Rate limit for TOR surpassed

Rate limit for TOR surpassed alarm

Alarm

Rate limit for TOR surpassed

Alarm Type

rateLimitTORSurpassed

Alarm Code

1302

Severity

Critical

Aggregation Policy

From the event code 1302 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 1301.

Attributef

"mvnoId”=”12”, “wlanId”=”1”, “zoneId”=”10”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”radiusd”,

“UserName”=abc@xyz.com, “realm”=”wlan.3gppnetwor"

"SCGMgmtIp"="2.2.2.2", “aaaSrvrIp”=”1.1.1.1” “AAAServerType”=”Auth/Acct”, “ueMacAddr”=”aa:bb:cc:gg:hh:ii”

“MOR”=1000, “THRESHOLD”=”500”, “TOR”=”501”

Displayed on the web interface

Maximum Outstanding Requests (MOR) surpassed for AAA Server [{aaaSrvrIp}] and ServerType [{AAAServerType}]. Dropping requests to be proxied to AAA.

Description

This alarm is triggered when maximum outstanding requests (MOR) is surpassed.

Recommended Actions

Download the SM log file from the controller web interface to check the error cause.