Cluster in maintenance state

Cluster in maintenance state alarm

Alarm

Cluster in maintenance state

Alarm Type

clusterInMaintenanceState

Alarm Code

804

Severity

Critical

Aggregation Policy

From the event code 807 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 808.

Attribute

“clusterName”=”xxx”

Displayed on the web interface

Cluster [{clusterName}] is in maintenance state

Description

This alarm is triggered when a cluster is in a maintenance state.

Recommended Actions

Possible causes:

  • The entire system backup is in process.
  • In a two-node cluster, the remove-node process is working.

For any other cause, please send the complete system log files (stored in the path - /opt/ ruckuswireless/controller/log/system to RUCKUS support for analysis.