Association down

Association down alarm

Alarm

Association down

Alarm Type

assocDown

Alarm Code

1627

Severity

Critical

Aggregation Policy

From the event code 1627 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 1628.

Attribute

“mvnoId”=”3”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”hip”, “srcIP”=”10.1.4.10”, “srcPort”=”2960”,

“destIP”=”10.1.4.20”, “destPort”=”2960”

Displayed on the web interface

SCTP association DOWN. srcIP [{srcIP}], srcPort [{srcPort}], destIP[{destIP}], destPort [{destPort}]

Description

This alarm is triggered when the stream control transmission protocol (SCTP) association is down.

Recommended Actions

Manual intervention is required.