Data plane packet pool is under low water mark

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

Data plane packet pool is under low water mark alarm

Alarm

Data plane packet pool is under low water mark

Alarm Type

dpPktPoolLow

Alarm Code

516

Severity

Major

Aggregation Policy

From the event code 516 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 518.

Attribute

"dpKey"="xx:xx:xx:xx:xx:xx", "id"="x"

Displayed on the web interface

Pool [{id}] on data plane [{dpName||dpKey}] is under low-water mark.

Description

This alarm is triggered when the data core packet pool is below the water mark level.

Recommended Actions

The operator needs to check for network looping.