ipmiThempFP

ipmiThempFP alarm

Alarm

ipmiThempFP

Alarm Type

ipmiThempFP

Alarm Code

903

Severity

Major

Aggregation Policy

From the event code 903 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 928.

Attribute

"id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"

Displayed on the web interface

Front panel temperature [{status}] on control plane [{nodeMac}]

Description

This alarm is triggered due to increase/decrease of the front panel temperature status of the control plane. Front panel threshold temperatures are in the range of 50 Celsius to 440 Celsius. The default threshold is 440C.

Recommended Actions

Check the fan module. Decrease the ambient temperature if the fan module is working.