This section displays the SNMP MIB objects for
temperature readings on the RUCKUS
FastIron
devices.
For stacking devices, refer to
System stacking temperature table. The system temperature table shows temperature reading information for each module’s
temperature sensor.
Name, OID, and syntax
|
Access
|
Description
|
| snAgentTempTable 1.3.6.1.4.1.1991.1.1.2.13.1
|
None
|
The table that displays the temperature reading for each module’s temperature sensor.
Note that temperature readings are displayed only for those modules that have temperature
sensors.
|
| snAgentTempSlotNum 1.3.6.1.4.1.1991.1.1.2.13.1.1.1 Syntax: Integer32
|
None
|
The slot number of the module to which the temperature sensor is attached.
|
| snAgentTempSensorId 1.3.6.1.4.1.1991.1.1.2.13.1.1.2 Syntax: Integer32
|
None
|
The identification number of the module’s temperature sensor.
The number of temperature sensors vary by switch model.
|
| snAgentTempSensorDescr 1.3.6.1.4.1.1991.1.1.2.13.1.1.3 Syntax: Display
string
|
Read-only
|
The description of the temperature sensor.
|
| snAgentTempValue 1.3.6.1.4.1.1991.1.1.2.13.1.1.4 Syntax: Integer
|
Read-only
|
The temperature reading for the temperature sensor. This value is displayed in units
of 0.5º Celsius.
|