| snAgentTempThreshold2Table 1.3.6.1.4.1.1991.1.1.2.13.4 SYNTAX: SEQUENCE OF
SnAgentTempThreshold2Entry
|
Table to list
temperature threshold levels for 3 speeds of fan settings, threshold
and warning temperature . Depending on the temperature level, the
fans run at different speeds. There are 3 levels of temperature
settings for 3 fan speeds (low, high, and shutdown). This table is
applicable to only those modules with temperature sensors. For each
row, there are 3 temperature threshold values. The 'high' value, if
reached, causes the fan to run at the next highest speed; when the
temperature reduces to below the 'low' value, the fan runs at the
next lowest speed.
|