SPX configuration CB SPX port table

The following MIB objects configure CB SPX ports for CB units. The following table objects are supported only on the RUCKUS ICX 7150, Brocade ICX 7250, RUCKUS ICX 7450, RUCKUS ICX 7650 and Brocade ICX 7750 devices.

Name, OID, and syntax

Access

Description

brcdSPXCBSPXPortTable

brcdIp.1.1.3.40.2.3

Not-accessible

The SPX configuration CB SPX port table.

brcdSPXCBSPXPortPort

brcdIp.1.1.3.40.2.3.1.1

Syntax: Integer32

Not-accessible

The IfIndex for the configured CB SPX port. The CB unit can have multiple SPX ports per unit.

brcdSPXCBSPXPortPEGroup

brcdIp.1.1.3.40.2.3.1.2

Syntax: DisplayString

Read-write

The name of IfIndex for the configured CB SPX port. It is an optional field.

brcdSPXCBSPXPortRowStatus

brcdIp.1.1.3.40.2.3.1.3

Syntax: Integer

Read-write

This object is used to delete row in the table and to control if they are used. The following values can be written:

  • delete(3) - Deletes the row
  • create(4) - Creates a new row

If the row exists, then a SET with a value of create(4) returns a 'wrongValue' error.

The following values can be returned on reads:

  • noSuchName - No such row
  • other(1) - Some other cases
  • valid(2) - The row exists and is valid