SD-LAN Support Over AP Ethernet Port

SD-LAN over AP Ethernet Ports allows supported AP LAN ports to be integrated into an SD-LAN deployment, enabling centralized management of wired endpoint connectivity through RUCKUS Edge.

Feature Overview

SD-LAN over AP Ethernet Port extends RUCKUS Edge SD-LAN services to wired devices connected to an AP LAN port. This feature enables the tunneling of Ethernet-connected devices—such as cameras, IP phones, and printers—through the RUCKUS Edge cluster to the core network, providing consistent policy enforcement for both wired and wireless clients.

The feature utilizes VxLAN-GPE to encapsulate wired traffic at the AP LAN port. The encapsulated traffic is tunneled to the RUCKUS Edge cluster, which then bridges the Layer 2 traffic to the core network via the configured Core port. This architecture allows administrators to extend SD-LAN benefits to wired IoT or office devices without requiring a separate WLAN. Additionally, a downstream switch connected to an AP LAN port can tunnel multiple VLANs to the Edge cluster.

Benefits

  • Unified Policy: Applies the same SD-LAN security and forwarding logic to wired devices.
  • Simplified Infrastructure: Eliminates the need for complex local VLAN management for wired IoT devices.
  • Scalability: Supports multiple VLANs via trunking on the AP LAN port.

Requirements

To utilize SD-LAN on AP Ethernet ports, the following system conditions must be met:

  • RUCKUS Edge firmware version 2.6.0 or later.
  • AP firmware version 7.2 (VxLAN-GPE) or later.
  • The RUCKUS Edge cluster must have a core port configured for SD-LAN.
  • APs must be onboarded to the target venue.
  • Supported AP models: H350, H550, H670, R550, R550, R560, R650, R670, R750, R760, R770, and R850.

Considerations

Consider the following when configuring and using this feature:

  • APs use VxLAN-GPE for tunneling. You must set the Tunnel Type to VxLAN GPE in all associated tunnel profiles.
  • SD-LAN on wired ports is configured at the venue level under LAN Ports, not at the individual AP level.
  • For a given AP model and LAN port ID in a venue, every AP of that model must have SD-LAN enabled on that port, or none.

Limitations

This feature includes the following limitation:

  • One SD-LAN service per venue: All wired LAN ports and wireless SD-LAN networks in a venue must use the same SD-LAN service.
  • Core port forwarding only: Tunneled traffic is forwarded through the Edge core port only; it is not supported for DMZ-Peer, L2oGRE, or vDP uplinks.
  • WAN/uplink port restriction: Enabling SD-LAN on the AP WAN/uplink port disconnects the AP from RUCKUS One.
  • Mutually exclusive with venue Wi-Fi DHCP: Wired-port SD-LAN cannot coexist with venue-level Wi-Fi DHCP in the same venue.
  • VLAN 1 restriction: VLAN 1 (default VLAN) UE traffic is not forwarded by Edge to the core network. Do not use VLAN 1 as the VLAN Untag ID or client VLAN on wired ports.
  • No statistics: SD-LAN tunnel statistics for AP wired ports are not available in this release.
  • MSP Delegation: EC tenants cannot create or pick MSP-owned SD-LAN services and cannot override wired SD-LAN at the AP level when delegation is active.

Best Practices

This feature has no special recommendations for feature enablement or usage.

Prerequisites

This feature has no prerequisites to feature enablement or usage.