RUCKUS Edge Gateway Service High Availability
In a high-availability deployment, one Edge node operates as the active gateway and the other operates as the standby gateway. If VRRP advertisements are no longer received, the standby node automatically assumes gateway responsibilities and begins forwarding traffic for the configured VLAN segments.
VRRP Transport VLAN
By default, VRRP communication uses VLAN 4080, which is reserved exclusively for VRRP traffic. VLAN 4080 must not be used for customer data traffic. The VRRP transport VLAN provides the communication path used by RUCKUS Edge nodes to exchange VRRP advertisements and maintain redundancy status. Although VLAN 4080 is used by default, RUCKUS One allows you to configure a different VLAN for VRRP communication.
High Availability Requirements
Ensure that the following requirements are met before deploying a high-availability Edge Gateway Service:
- Two Edge nodes are installed and configured as a cluster.
- Each Edge node has a dedicated WAN IP address.
- The VRRP transport VLAN transparently forwards xSTP BPDUs between peers.
- Create the VRRP transport VLAN on the ICX switch with the necessary port membership.
- Segment-to-port associations are configured identically on both Edge nodes.
Failover Behavior
- The active node hosts the VLAN gateway interfaces and forwards traffic.
- The standby node maintains synchronized configuration but does not actively forward VLAN traffic.
- VLAN segment configuration is synchronized between both nodes.