Configuring AP Ethernet Ports for SD-LAN Service — MSP Edge Delegation

In MSP-EC deployments, the MSP owns and manages the Edge cluster, SD-LAN services, and associated configuration templates. The MSP creates and applies templates, including tunnel profiles, SD-LAN services, Ethernet port profiles, and venue templates, to customer tenants from the MSP portal.

End Customer (EC) administrators can view and perform limited modifications to delegated venue configurations; however, they cannot create, modify, or delete MSP-managed SD-LAN services.

MSP-EC deployments use MSP-managed templates for service provisioning rather than direct service creation, and EC administrators cannot override AP-level SD-LAN configurations or modify MSP-owned SD-LAN services.

Ensure that the following prerequisites are met:
  • Onboard the destination RUCKUS Edge cluster to the MSP tenant before creating the Tunnel Profile Template.
  • The MSP tenant has an onboarded RUCKUS Edge cluster with a Core port configured for SD-LAN.
  • At least one EC tenant is available under the MSP account.
  • The target APs are onboarded to the destination EC venue.
Complete the following steps in the MSP tenant to configure AP Ethernet ports for an SD-LAN service.
  1. Create an Ethernet Port Profile Template.
  2. (Optional) Create IPsec Profile Template.
  3. Create a Tunnel Profile template.
  4. Create an SD-LAN service for MSP account.
    Refer to Adding an SD-LAN Service for an MSP Account for more information.
  5. Create a Venue template.
  6. Configure LAN ports in Venue template.
  7. Apply configuration templates to EC tenants.
  8. Synchronize templates across EC tenants.