Supported ICX Models
This is a
shared topic reused across multiple customer-facing FastIron and SmartZone
publications. Please respect the contents and do not make changes to versions,
feature names, model names, or any other substantive text unless the changes
have been reviewed by at least one subject matter expert, preferably the product
PM. Please notify the SmartZone and FastIron writing team of any approved
changes.
The following ICX switch models can be managed from
SmartZone:
ICX Firmware Versions Compatible with SmartZone
| ICX Model | First Supported FastIron-SZ Compatible Release | Last Supported FastIron Release |
|---|---|---|
| ICX 715012 | 08.0.80a | 09.0.10a and subsequent patches 10.0.10f and subsequent patches |
| ICX 7150-C08P, -C08PT | 08.0.92 | 09.0.10a and subsequent patches |
| ICX 7250 | 08.0.80a | 09.0.10a and subsequent patches |
| ICX 7450 | 08.0.80a | 09.0.10a and subsequent patches |
| ICX 7550 | 08.0.95a | - |
| ICX7550-4X25GF | 10.0.10h | |
| ICX 7650 | 08.0.80a | - |
| ICX 7750 | 08.0.80a | 08.0.95 and subsequent patches |
| ICX 7850 | 08.0.90 | - |
| ICX 7850-48C | 09.0.10a | - |
| ICX 8100-24, -24P, -48, -48P, -C08PF | 10.0.10f_cd1 | - |
| ICX 8100-24-X, -24P-X, -48-X, -48P-X, -C08PF-X | 10.0.10g_cd1 | - |
| ICX 8100-48PF, -48-PF-X, 16PF-X, 16PF, -C16P, -C16P-X | 10.0.10h_cd1 | - |
| ICX 8200-24, -24P, -48, -48P, -48PF, -48PF2, -C08PF | 10.0.003 | - |
| ICX 8200-24ZP, -48ZP2, -24FX, -24F, -48F, -C08ZP | 10.0.10 | - |
| ICX 8200-24PV and ICX 8200-C08PFV | 10.0.10e | - |
The following table defines ICX and SmartZone release compatibility.
Note: ICX
switches must be running FastIron 08.0.80a at a minimum to connect to
SmartZone.
An ICX switch running unsupported firmware can still connect to the SmartZone controller. After the switch is connected, you must upgrade it to a firmware version that is compatible with the SmartZone controller version.
Note: FastIron 09.0.10a and later
releases support management by SmartZone 6.1 and later.
Apply conditions as needed to remove data for unreleased
versions. Rows at the end of the table can be conditioned out without format
issues. Confirm the output looks correct, however, if conditions have been
applied.
Note: ICX switches with FIPS mode
enabled do not support management by SmartZone.
ICX and SmartZone Release Compatibility Matrix
| SmartZone 5.1.1 | SmartZone 5.1.2 | SmartZone 5.2 | SmartZone 5.2.1 / 5.2.2 | SmartZone 6.0 | SmartZone 6.1 | SmartZone 6.1.1 | SmartZone 6.1.2 | SmartZone 7.0.0 | SmartZone 7.1 | SmartZone 7.1.1 | SmartZone 7.2 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FastIron 08.0.90a | Yes | Yes | Yes | Yes | Yes | No | No | No | No | No | No | No |
| FastIron 08.0.91 | Yes | Yes | Yes | No | No | No | No | No | No | No | No | No |
| FastIron 08.0.92 | No | Yes | Yes | Yes | Yes | Yes | No | No | No | No | No | No |
| FastIron 08.0.95 and subsequent patches | No | No | No | No | Yes | Yes | Yes | Yes | No | No | No | No |
| FastIron 09.0.10a and subsequent patches | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | No | No |
| FastIron 10.0.00 and subsequent patches4 | No | No | No | No | No | No | Yes | Yes | Yes | Yes | No | No |
| FastIron 10.0.10 and subsequent patches | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Switch Management Feature Compatibility Matrix
| Feature | SmartZone Release | ICX FastIron Release |
|---|---|---|
| Switch Registration | 5.0 and later | 08.0.80 and later |
| Switch Inventory | 5.0 and later | 08.0.80 and later |
| Switch Health and Performance Monitoring | 5.0 and later | 08.0.80 and later |
| Switch Firmware Upgrade | 5.0 and later | 08.0.80 and later |
| Switch Configuration File Backup and Restore | 5.0 and later | 08.0.80 and later |
| Client Troubleshooting: Search by Client MAC Address | 5.1 and later | 08.0.80 and later |
| Remote Ping and Traceroute | 5.1 and later | 08.0.80 and later |
| Switch Custom Events | 5.1 and later | 08.0.80 and later |
| Remote CLI Change | 5.2.1 and later | 08.0.90 and later |
| Switch Configuration: Zero-Touch Provisioning | 5.1.1 and later | 08.0.90a and later |
| Switch-specific Settings: Hostname, Jumbo Mode, IGMP Snooping, and DHCP Server | 5.1.1 and later | 08.0.90a and later |
| Switch Port Configuration | 5.1.1 and later | 08.0.90a and later |
| Switch AAA Configuration | 5.1.1 and later | 08.0.90a and later |
| Switch Client Visibility | 5.1.2 and later | 08.0.90a and later |
| Manage Switches from Default Group in SZ-144 / vSZ-E | 5.1.2 and later | 08.0.90a and later |
| DNS-based SmartZone Discovery | 5.1.2 and later | 08.0.95c and later |
| Download Syslogs for a Selected Switch5 | 5.2.1 and later | 08.0.92 and later |
| Switch Topology | 5.2 and later | 08.0.92 and later |
| Designate a VLAN as Management VLAN | 5.2.1 and later | 08.0.92 and later6 |
| Change Default VLAN | 5.2.1 and later | 08.0.95 and later |
| Configure the PoE Budget per Port on ICX through the Controller GUI with 1W Granularity | 5.2.1 and later | 08.0.95 and later |
| Configuring Protected Ports | 5.2.1 and later | 08.0.95 and later |
| Configuring QoS | 5.2.1 and later | 08.0.95 and later |
| Configuring Syslog | 5.2.1 and later | 08.0.95 and later |
| Geo Redundancy Active-Standby Mode | 6.0 and later | 08.0.95b and later |
| Generic CLI Configuration | 6.0 and later | 08.0.95b and later |
| Port-Level Override | 6.0 and later | 08.0.95b and later |
| Port-Level Storm Control Configuration | 6.1 and later | 08.0.95 and later |
| IPv6 Support (connection through static configuration only) | 6.1 and later | 09.0.10a and later |
| Save Boot Preference | 6.1 and later | 09.0.10a and later |
| Virtual Cable Testing | 6.1 and later | 09.0.10a and later |
| Blink LEDs | 6.1 and later | 09.0.10a and later |
| Send Event Email Notifications at Tenant Level | 6.1 and later | 09.0.10a and later |
| Update the status of a Switch | 6.1 and later | 09.0.10a and later |
| Convert Standalone Switch | 6.1 and later | 09.0.10a and later |
| Flexible Authentication Configuration | 6.1 and later | 09.0.10a and later |
| Network Segmentation | 6.1.1 and later | 09.0.10d and later7 |
| Enhancement in Firmware Upgrade Status | 7.0.0 and later | 09.0.10h and later |
| SmartZone Usernames in ICX Syslogs | 7.0.0 and later | 09.0.10h and later, 10.0.10c and later |
| Configuring Separate Authentication and Accounting in AAA server | 7.0.0 and later | 09.0.10h and later |
| SmartZone support the ICX 8200-24PV and ICX 8200-C08PFV models. | 7.1.1 and later | 10.0.10e and later |
| SmartZone support the ICX 8100 Static Routing and Maximum Virtual Interface | 7.2.0 and later | 10.0.10h and later |
| SmartZone support the ICX 8100-X 10G uplink models. | 7.2.0 and later | 10.0.10h and later |
| ICX custom events trigger time window | 7.2.0 and later | 10.0.10h and later |
| Displays port traffic numbers and percentages on SmartZone | 7.2.0 and later | 10.0.10h and later |
| ICX supports port-level storm control rate limiting with threshold configuration | 7.2.0 and later | 09.0.10k and later |
| Enabling IPv6 configuration options in IPv4 mode | 7.2.0 and later | 10.0.10f and later |
| Improves switchover cluster architecture and adding a license check mechanism | 7.2.0 and later | 10.0.10h and later |
- SmartZone does not support ICX 7150-ES devices. ↩
- ICX 7150 devices are not supported on FastIron 10.0.x releases prior to FastIron 10.0.10d. This includes FastIron 10.0.00 and FastIron 10.0.10 through 10.0.10c. ↩
- RUCKUS recommends upgrading switches running FI 10.0.00 (or subsequent patch releases) to FI 10.0.10 firmware. Refer to the recommended version on the RUCKUS Support Portal to find the specific version within the 10.0.10 release train. ↩
- RUCKUS recommends upgrading switches running FI 10.0.00 (or subsequent patch releases) to FI 10.0.10 firmware. Refer to the recommended version on the RUCKUS Support Portal to find the specific version within the 10.0.10 release train. ↩
- To download system logs from SmartZone for a particular ICX switch, TFTP must be enabled. ↩
- FastIron 10.0.00 and later releases do not support management VLANs. ↩