Setting Module 2 to Uplink-100-Gbps Mode
Breakout is supported only on module 2
in all ICX 7550 models. Use the slot 2 uplink-100g
command to set module 2 uplink-100-Gbps mode on the ICX 7550-24ZP, ICX 7550-48ZP,
ICX 7550-24F, and ICX 7550-48F models. When slot 2 uplink-100g is
configured, the supported modules in module 3 are 4x10-Gbps or 1x100-Gbps.
- Enter global configuration mode.
- Enter the slot 2 uplink-100g
command to configure module 2.
ICX7550-48F Router(config)# slot 2 uplink-100g Changes require reload to take effect. Please do write memory and then reload or power cycle!!! Slot 2 will be operating in uplink mode with 100Gbps speed after reload
ICX7550-48F Router(config)# exit ICX7550-48F Router# write memory ICX7550-48F Router# reload
- Enter the
show running-configcommand to display the running configuration.