Traps for stacking

The following table has traps for stacking.

Trap name and number

Varbinds

Severity

Description and trap message

       
snTrapStackingMasterElected

brcdIp.0.163

snChasUnitIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when a unit is elected as the Master unit for the stacking system.

Sample trap message:

Stack unit <unitNumber> has been elected as ACTIVE unit of the stack system

snTrapStackingUnitAdded

brcdIp.0.164

snChasUnitIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when a unit has been added to the stacking system.

Sample trap message:

Stack: Stack unit <unitNumber> has been added to the stack system

snTrapStackingUnitDeleted

brcdIp.0.165

snChasUnitIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when a unit has been deleted from the stacking system.

Sample trap message:

Stack: Stack unit <unitNumber> has been deleted to the stack system

snTrapStackingChasPwrSupplyOK

brcdIp.0.166

snChasUnitIndex, snChasPwrSupplyIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when a power supply operational status changed from failure to normal for a stacking system.

Sample trap message:

System: Stack unit <unitNumber> Power supply <snChasPwrSupplyIndex> is up

snTrapStackingChasPwrSupplyFailed

brcdIp.0.167

snChasUnitIndex, snChasPwrSupplyIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when a power supply operational status changed from normal to failure for a stacking system.

Sample trap message:

System: Stack unit <unitNumber> Power supply <snChasPwrSupplyIndex> is down

snTrapStackingChasFanNormal

brcdIp.0.168

snChasUnitIndex, snChasFanIndex, snChasFanDescription

Minor

The SNMP trap that is generated when a fan operational status changed from failure to normal for a stacking system.

Sample trap message:

System: Stack unit <unitNumber> Fan <snChasFanIndex> (<snChasFanDescription>), ok

snTrapStackingChasFanFailed

brcdIp.0.169

snChasUnitIndex, snChasFanIndex, snChasFanDescription

Minor

The SNMP trap that is generated when a fan fails to operate normally for a stacking system.

Sample trap message:

System: Stack unit <unitNumber> Fan <snChasFanIndex> (<snChasFanDescription>), failed

snTrapStackingManagementMAC Changed

brcdIp.0.170

snAgGblTrapMessage

Minor

The SNMP trap that is generated when the managemnet MAC address of a stacking system has been changed.

Sample trap message:

System: Management MAC address changed to <mac_address>

snTrapStackingTemperatureWarning

brcdIp.0.171

snChasUnitIndex, snAgGblTrapMessage

Minor

The SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold for a stack sytem.

Sample trap message:

System: Stack unit <unitNumber> Temperature <actual-temp> C degrees, warning level <warning-temp> C degrees, shutdown level <shutdown-temp> C degrees

snTrapStackingMixedModeChanged

brcdIp.0.199

snStackingGlobalMixedMode, snAgGblTrapMessage

Notification

The SNMP trap that is generated when a stacking system mode is changed.

snTrapStackingShowStack Connect

brcdIp.0.209

snAgGblTrapMessage

Notification

The SNMP trap is generated when the background diagnosis detects the connection errors to notify the user to check the connections in a stacking system.

Format: Background diagnosis detects connection errors. Please use show stack conn to view detailed connections.

snTrapStackingStandByChanged Standalone

brcdIp.0.210

snChasUnitIndex, snAgGblTrapMessage

Notification

The SNMP trap is generated when a unit is changed from Standby to Standalone when the active unit is down.

snTrapStackISSUSystemCompleted

brcdIp.0.215

snAgGblTrapMessage

Notification

The SNMP trap is generated when system completed stack upgrade process.

snTrapStackISSUSystemFailed

brcdIp.0.216

snAgGblTrapMessage

Alerts

The SNMP trap is generated when system failed stack upgrade process.

snTrapStackISSUUnitCompleted

brcdIp.0.217

snChasUnitIndex, snAgGblTrapMessage

Notification

The SNMP trap is generated when unit completed upgrade process.

Format: Stack: stack unit <unit_id> completed upgrade

snTrapStackISSUUnitFailed

brcdIp.0.218

snChasUnitIndex, snAgGblTrapMessage

Alerts

The SNMP trap is generated when unit failed upgrade process.

Format: Stack: system upgrade failed, stack unit <unit_id> is in failure state

snTrapStackISSUSystemStart

brcdIp.0.219

snAgGblTrapMessage

Notification

The SNMP trap is generated when system starts stack upgrade process.

Format: Stack: system upgrade started and most of user interfaces are blocked

snTrapStackingIgnoreShutdown TemperatureThresholdEnabled

brcdIp.0.220

snChasUnitIndex

snAgGblTrapMessage

Alerts

The SNMP trap is generated when Ignore Shutdown Temperature Threshold is enabled for a stack unit.

snTrapStackingIgnoreShutdown TemperatureThresholdDisabled

brcdIp.0.221

snChasUnitIndex

snAgGblTrapMessage

Alerts

"The SNMP trap is generated when Ignore Shutdown Temperature Threshold is disabled for a stack unit.