Traceroute Control Table Objects MIB

MIB objects

Objects and OID Access Description
traceRouteCtlOwnerIndex

Syntax: SnmpAdminString (SIZE(0..32))

None This first index for the entry in traceRouteCtlTable. The value is textually mapped to a securityName or groupName defined in VACM.
traceRouteCtlTestName

Syntax: SnmpAdminString (SIZE(0..32))

None The name of the traceroute test. This is locally unique, within the scope of a traceRouteCtlOwnerIndex.
traceRouteCtlTargetAddressType

Syntax: InetAddressType

Read-create Specifies the type of host address to be used on the traceroute request at the remote host. The following values are supported.

  • ipv4(1)
  • ipv6(2)

traceRouteCtlTargetAddress

Syntax: InetAddress

Read-create

Specifies the host address used on the traceroute request at the remote host.

A value for this object must be set prior to transitioning its corresponding traceRouteCtlEntry to active(1) via traceRouteCtlRowStatus. The default value is 00 00 00 00.

traceRouteCtlTimeOut

Syntax: Unsigned32 (0..60)

Read-create Specifies the time-out value, in seconds,for a traceroute request.
Note: Default Value 3 Seconds.
traceRouteCtlMaxTtl

Syntax: Unsigned32 (1..255)

Read-create Specifies the maximum time-to-live value.
Note: Default value is 30.
traceRouteCtlSourceAddressType

Syntax: InetAddressType

Read-create Specifies the type of the source address, traceRouteCtlSourceAddress. Default value is unknown.
Note: IPv4 and IPv6 are supported.
traceRouteCtlSourceAddress

Syntax: InetAddress

Read-create Use the specified IP address (which must be given as an IP number, not as a hostname) as the source address in the outgoing probe packets. On hosts with more than one IP address, this option is used to select the address to be used. If the IP address is not one of the interface addresses of the machine, an error is returned, and nothing is sent. A zero-length octet string value for this object disables source address specification.
Note: Host name is not supported. Specify IPv4 or IPv6 address.
traceRouteCtlInitialTtl

Syntax: Unsigned32 (1..255)

Read-create

The value of this object specifies the initial TTL value to use. This enables bypassing the initial (often well known) portion of a path. Default value is 1.

traceRouteCtlStorageType

Syntax: StorageType

Read-create The storage type for this conceptual row. Conceptual rows having the value ’permanent’ need not allow write-access to any columnar objects in the row.
Note: Only Read-only access supported for this object. The object always returns value of volatile(2) (is lost upon reboot).
traceRouteCtlAdminStatus

Syntax:

INTEGER
Read-create

This object defines the state of traceRouteCtlEntry.

enabled(1) - operation should be started.

disabled(2) - operation should be stopped

'Disabled' is the default value.

traceRouteCtlDescr

Syntax: SnmpAdminString

Read-create Descriptive name of the remote traceroute test. Maximum 255 characters.
traceRouteCtlMaxRows

Syntax: Unsigned32

Read-create

The maximum number of corresponding entries allowed in the traceRouteProbeHistoryTable. A value of 0 for this object disables creation of traceRouteProbeHistoryTable entries. The default value is 50.

Note: Only Read-only access supported for this object.
traceRouteCtlTrapGeneration

Syntax: BITS {

pathChange(0),

testFailure(1),

testCompletion(2)

}

Read-create

The value of this object determines when and whether to generate a notification for this entry:

pathChange(0) - Generate a traceRoutePathChange notification when the current path varies from a previously determined path.

testFailure(1) - Generate a traceRouteTestFailed notification when the full path to a target can't be determined.

testCompletion(2) - Generate a traceRouteTestCompleted notification when the path to a target has been determined.

traceRouteCtlCreateHopsEntries

Syntax: TruthValue

Read-create The current path for a traceroute test is kept in the traceRouteHopsTable on a per-hop basis when the value of this object is true(1).
Note: Only Read-only access supported for this object.
traceRouteCtlType

Syntax: OBJECT IDENTIFIER

Read-create The value of this object is used either to report or to select the implementation method to be used for performing a traceroute operation. The value of this object may be selected from traceRouteImplementationTypeDomains.
Note: Only Read-only access supported for this object.
traceRouteCtlRowStatus

Syntax: RowStatus

Read-create This object allows entries to be created and deleted in the traceRouteCtlTable. Deletion of an entry in this table results in a deletion of all corresponding (same traceRouteCtlOwnerIndex and traceRouteCtlTestName index values) traceRouteResultsTable, traceRouteProbeHistoryTable, and traceRouteHopsTable entries.

History

Release version History
08.0.80a This MIB was introduced.