The switch group configuration table is supported on the
RUCKUSFastIron devices.
Name, OID, and syntax
Access
Description
snSwGroupOperMode
brcdIp.1.1.3.1.1
Syntax: Integer
Read-write
Indicates if switch ports have VLANs defined:
noVLan(1) - All switch ports with no port VLANs and no tag assigned.
vlanByPort(2) - All switch ports with basic port-based VLANs.
snSwGroupIpL3SwMode
brcdIp.1.1.3.1.2
Syntax: Integer
Read-write
Indicates if the Layer 3 IP switch is enabled for the switch group:
disabled(0)
enabled(1)
snSwGroupIpMcastMode
brcdIp.1.1.3.1.3
Syntax: Integer
Read-write
Indicates if the IP multicast pruning mode is enabled for the switch group:
disabled(0)
active(1)
passive(2)
snSwGroupDefaultCfgMode
brcdIp.1.1.3.1.4
Syntax: Integer
Read-write
Indicates if the switch group contains a default configuration. If the default configuration
is overwritten, the state will change to non-default:
default(1) - Has a default configuration.
nonDefault(2) - Has a non-default configuration.
snSwGroupSwitchAgeTime
brcdIp.1.1.3.1.5
Syntax: Integer32
Read-write
Sets the aging period for ports on the device, defining how long a port address remains
active in the address table.
Valid values: 0 = no aging, or 67 - 65535 seconds
Default: 300 seconds
snVLanGroupVlanCurEntry
brcdIp.1.1.3.1.6
Syntax: Integer32
Read-only
Shows the number of VLANs that are currently configured.
snFdbTableCurEntry
brcdIp.1.1.3.1.9
Syntax: Integer32
Read-only
Shows the total number of entries in the Filtering Databse (FDB) that are configured
currently.
snFdbTableStationFlush
brcdIp.1.1.3.1.10
Syntax: Integer
Read-write
Shows the state of the flush operation for the FDB table.
The following value can be written:
flush(3) - Perform the flush operation. After the flush operation starts, any new
flush request is rejected until the operation is complete or failed.
The following values can only be read:
normal(1) - Normal state
error(2) - Operation failed
flushing(4) - Operation is in process
snPortStpSetAll
brcdIp.1.1.3.1.11
Syntax: Integer32
Read-write
The value of this object is 1, which means that Port STP
Set-all command is invoked. The snPortStpPriority and snPortStpPathCost which are the read-write
STP-related attributes of the first row of the table, will be used to set the same
attributes for all the ports in the system.
Note: Before setting this object, all the intended attributes of the given row of the table
must be set. Otherwise, the current data of the row will be used to set the entire
port table. The previous setting will be overwritten by the new one.
snSwProbePortNum
brcdIp.1.1.3.1.12
Syntax: Integer32
Read-write
Indicates which chassis port is assigned as the chassis switch probe port. That port
operates as a traffic analyzer port. Only one port in the chassis or stackable switch
can be assigned as the traffic analyzer port. The value of this object represents
the following:
Bit 0 to bit 7 - Port number
Bit 8 to bit 11 - Slot number
snSw8021qTagMode
brcdIp.1.1.3.1.13
Syntax: Integer
Read-write
Indicates if IEEE802.1q has been enabled for the switch group:
disabled(0)
enabled(1)
Default: disabled(0)
snSwGlobalStpMode
brcdIp.1.1.3.1.14
Syntax: Integer
Read-write
Indicates whether or not Spanning Tree System Global Mode has been enabled for the
switch group:
disabled(0)
enabled(1)
snSwIpMcastQuerierMode
brcdIp.1.1.3.1.15
Syntax: Integer
Read-write
The IP Multicast pruning mode is configured in either Non-Querier or Querier mode.
querier(1) - Send out host queries. (active)
nonQuerier(2) - Do not send out host queries. (passive)
Default: querier(1)
snSwViolatorPortNumber
brcdIp.1.1.3.1.17
Syntax: Integer32
Read-only
Indicates the port number of the switch or router that receives the violator packet.
This number is included in the locked address violation trap. The value of this object
contains the following:
Bit 0 to bit 7 - Port number
Bit 8 to bit 11 - Slot number (for chassis devices only)
snSwViolatorMacAddress
brcdIp.1.1.3.1.18
Syntax: MAC address
Read-only
Indicates the source MAC address of the violator packet received by the switch or
router. This number is included in the locked address violation trap.
snVLanGroupVlanMaxEntry
brcdIp.1.1.3.1.19
Syntax: Integer32
Read-write
Shows the maximum number of VLAN entries that can be configured.
snSwEosBufferSize
brcdIp.1.1.3.1.20
Syntax: Integer32
Read-only
Specifies buffer size for all the different EOS buffers.
snSwPortEntrySize
brcdIp.1.1.3.1.22
Syntax: Integer32
Read-only
Specifies the size of each port table entry.
snFdbStationEntrySize
brcdIp.1.1.3.1.23
Syntax: Integer32
Read-only
Specifies the size of each FDB station table entry.
snPortStpEntrySize
brcdIp.1.1.3.1.24
Syntax: Integer32
Read-only
Specifies the size of each port STP table entry.
snSwEnableBridgeNewRootTrap
brcdIp.1.1.3.1.25
Syntax: Integer
Read-write
Indicates whether the SNMP agent process is permitted to generate bridge new root
traps.
snSwEnableBridgeTopoChangeTrap
brcdIp.1.1.3.1.26
Syntax: Integer
Read-write
Indicates whether the SNMP agent process is permitted to generate bridge topology
change traps.
snSwClearCounters
brcdIp.1.1.3.1.33
Syntax: Integer
Read-write
Clears software counters:
valid(0) - An SNMP-GET of this MIB shows that it is a valid command to use.
clear(1) - Clear counter commands of the following counters: Dot3, MIB2, IP, and IPX
counters for all ports.
snSw8021qTagType
brcdIp.1.1.3.1.34
Syntax: Integer32
Read-only
Specifies the IEEE802.1q tag type that is embedded in the length or type field of
an Ethernet packet. It specifies that the two octets after the length or type field
in an Ethernet packet are the tag value.
Default: 33024
snSwBroadcastLimit
brcdIp.1.1.3.1.35
Syntax: Integer32
Read-write
Specifies the number of broadcast packets per second. This limits the number of broadcast
packets to forward out of the switch ports. Setting this object to 0 disables the
limitation check.
Default: 0
snSwMaxMacFilterPerSystem
brcdIp.1.1.3.1.36
Syntax: Integer32
Read-only
Specifies the maximum number of MAC filters per system in the MAC filter table.
snSwMaxMacFilterPerPort
brcdIp.1.1.3.1.37
Syntax: Integer32
Read-only
Specifies the maximum number of MAC filters per port in the port MAC access filter
table.
snSwDefaultVLanId
brcdIp.1.1.3.1.38
Syntax: Integer
Read-write
Shows the VLAN ID of the default port VLAN.
Valid values: 1 - 4095
snSwGlobalAutoNegotiate
brcdIp.1.1.3.1.39
Syntax: Integer
Read-write
Applies only to Gigabit Ethernet ports.
Specifies the negotiation mode of the port:
disable(0) - All Gigabit Ethernet ports are in non negotiation mode.
enable(1) - All Gigabit Ethernet ports will start auto-negotiation indefinitely until
they succeed.
negFullAuto(2) - All Gigabit Ethernet ports will start with auto-negotiation. If the
negotiation fails, then they will automatically switch to non-negotiation mode. Gigabit
Ethernet ports on all stackable products do not support negFullAuto(2).
other(3)
Default: negFullAuto(2)
snSwQosMechanism
brcdIp.1.1.3.1.40
Syntax: Integer
Read-write
Specifies the Quality of Service (QoS) mechanism:
strict(0)
weighted(1)
Default: weighted(1)
snSwSingleStpMode
brcdIp.1.1.3.1.41
Syntax: Integer
Read-write
Indicates if the Single Spanning Tree System Mode in the Switch Group is enabled:
disabled(0)
enabled(1)
Default: disabled(0)
snSwFastStpMode
brcdIp.1.1.3.1.42
Syntax: Integer
Read-write
Indicates if Fast Spanning Tree System Mode in the Switch Group is enabled:
disabled(0)
enabled(1)
snSwSingleStpVLanId
brcdIp.1.1.3.1.44
Syntax: Integer32
Read-only
The VLAN ID of the Single Spanning Tree VLAN if Single Spanning Tree was enabled.
This object returns zero if Single Spanning Tree was disabled.
snSwJumboMode
brcdIp.1.1.3.1.45
Syntax: Integer
Read-only
Jumbo mode enables support of the jumbo frame (10200 bytes). Jumbo mode can be enabled
or disabled; the default is enabled mode.
Please note that enabling/disabling jumbo mode will take effect only after saving
the configuration and performing a system reload.
disabled(0)
enabled(1)
snSwIpMcastVersion
brcdIp.1.1.3.1.47
Syntax: Integer32
Read-write
Sets the Multicast version at the global level
Values are 2 or 3. The default is 2.
snSwErrDisableRecoveryTimeout
brcdIp.1.1.3.1.49
Syntax: Unsigned
32
Read-write
The Error-Disable timeout value in seconds
Valid Values: 0 to 65535
Default Value: 300
snSwErrDisableRecoveryCause
brcdIp.1.1.3.1.50
Syntax:
Unsigned 32
Read-write
Configures the errdisable cause support recovery.
Valid values:
0 = no recovery is supported, or other value
bit 0 - Enable auto-recovery from all causes
bit 1 - Enable auto-recovery from BPDU guard
bit 2 - Enable auto-recovery from loop-detection
bit 4 - Enable auto-recovery from packet inError
bit 5 - Enable auto-recovery from LOAM remote critical event
bit 12 - Enable auto-recovery from pvstplus-protect
bit 13 - Enable auto-recovery from bpdu tunnel threshold
bit 14 - Enable auto-recovery from lag operational speed
mismatch