Replacing a stack unit automatically with a clean unit
-
Replace examples with non-ICX 7750 examples.(Optional) Enter the
show stackcommand on the active controller, and check for an "S" beside the unit to confirm that the configuration for the unit you are replacing is static. - If the configuration is not static, enter the
write memorycommand to change all dynamic configurations to static. A static configuration remains after the unit is removed.After the configuration is saved with thewrite memorycommand, all unit IDs are followed by an "S" as shown in the following example.ICX7750-26Q Router# show stack T=3h24m36.1: alone: standalone, D: dynamic cfg, S: static ID Type Role Mac Address Pri State Comment 1 S ICX7750-26QXG active cc4e.2438.7280 128 local Ready 2 S ICX7750-48XGF member 609c.9f7f.9400 0 remote Ready 3 S ICX7750-26QXG standby 748e.f8f9.6300 0 remote Ready active standby +---+ +---+ +---+ =2/1| 1 |2/4==2/1| 3 |2/4==2/4| 2 |2/1= | +---+ +---+ +---+ | | | |-------------------------------------|When you remove a unit with a static configuration, the configuration is still present. Theshow stackcommand output lists the unit state as "reserve" as shown in the following example for unit 2.ICX7750-26Q Router# show stack T=3h25m53.4: alone: standalone, D: dynamic cfg, S: static ID Type Role Mac Address Pri State Comment 1 S ICX7750-26QXG active cc4e.2438.7280 128 local Ready 2 S ICX7750-48XGF member 0000.0000.0000 0 reserve 3 S ICX7750-26QXG standby 748e.f8f9.6300 0 remote Ready active standby +---+ +---+ 2/1| 1 |2/4==2/1| 3 |2/4 +---+ +---+ - Remove the old unit from the stack.
Although the unit is absent, the provisional configuration for the unit is still retained on the active controller.
- Make sure that the hardware (module) configuration of the replacement unit is identical to the hardware configuration of the unit you removed.
- Connect the new unit to the stack using the same stacking ports as the old unit.
If the replacement unit configuration matches the configuration retained on the active controller, the active controller resets the new unit. The new unit becomes a member and joins the stack, and the stack keeps its original topology.