Manually Allocating the Stack MAC Address
When a stack is enabled, “hitless-failover enable” configuration is added, and a default
stack MAC address is assigned if none is configured. The address assigned is the MAC
address of the unit as shown in the output of the
show stack command.
The MAC address is a hexadecimal number in the format xxxx.xxxx.xxxx.
If necessary, you can manually configure the stack to use a specific MAC address.
stack mac command may be useful for administrative purposes; however, it should be used with
caution to prevent duplication of MAC addresses.
To configure a stack MAC address manually, enter the following command in device configuration mode.
device# configure terminal device(config)# stack mac 0000.0000.0011
no form of the
stack mac command to revert to the use of the active controllers' MAC address.
The following example shows the stack MAC address being configured manually as confirmed
in the
show running-config command output.
ICX7750-26Q Router# configure terminal ICX7750-26Q Router(config)# stack mac 0000.0000.0011 ICX7750-26Q Router(config)# show running-config Current configuration: ! ver 08.0.90 ! stack unit 1 module 1 icx7750-20-qxg-port-management-module module 2 icx7750-qsfp-6port-qsfp-240g-module module 3 icx7750-6q-6port-qsfp-240g-module priority 255 stack-port 1/2/1 stack-port 1/2/4 stack unit 2 module 1 icx7750-20-qxg-port-management-module module 2 icx7750-qsfp-6port-qsfp-240g-module module 3 icx7750-6q-6port-qsfp-240g-module priority 240 stack-port 2/2/1 stack-port 2/2/4 stack enable stack mac 0000.0000.0011 !
To display the stack MAC address (the Management MAC address, the MAC address of
the first port of the active controller), enter the
show chassis
command.
ICX7450-48F Router# show chassis
The stack unit 1 chassis info:
Power supply 1 (AC - Regular) present, status ok
Model Number: 23-0000144-02
Serial Number: 0L8
Firmware Ver: A
Power supply 1 Fan Air Flow Direction: Front to Back
Power supply 2 not present
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2
Fan controlled temperature: 62.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->63 deg-C
Speed 2: 53<-----> 80 deg-C (shutdown)
Fan 1 Air Flow Direction: Front to Back
Fan 2 Air Flow Direction: Front to Back
Slot 1 Current Temperature: 44.5 deg-C (Sensor 1), 62.5 deg-C (Sensor 2), 52.0 deg-C (Sensor 3), 41.5 deg-C (Sensor 4), 54.5 deg-C (Sensor 5)
Slot 2 Current Temperature: 41.0 deg-C (Sensor 1)
Slot 3 Current Temperature: 45.0 deg-C (Sensor 1)
Slot 4 Current Temperature: 45.0 deg-C (Sensor 1)
Warning level.......: 70.0 deg-C
Shutdown level......: 80.0 deg-C
Boot Prom MAC : cc4e.246d.1378
Management MAC: cc4e.246d.1378
show chassis command, refer to
Displaying stack chassis information.