clear chassis unit-id
Global configuration mode
When the Power Supply DC LED is blinking red, indicating that the power supply has detected an over-current condition, the warning light can be cleared using this command.
This command is supported for ICX 8200 and ICX 8100 devices only.
The following example clears PSU 1 over the current warning LED for an ICX 8200 standalone device.
ICX8200-48ZP2 Router# clear chassis unit-id 1 ps-device 1 led ICX8200-48ZP2 Router#clear chassis unit-id 1 ps-device 2 led (To clear PSU 2 over current warning led)
The following example clears PSU 2 over the current warning LED for an ICX 8200 standalone device.
ICX8200-48ZP2 Router# clear chassis unit-id 1 ps-device 2 led
The following example clears PSU 1 and PSU2 over the current warning LED of unit id 3 for a stack setup.
show stack
T=2m46.2: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX8200-48PF active c0c5.2080.1bbc 0 local Ready
2 S ICX8200-48P standby c0c5.2080.23f6 0 remote Ready
3 D ICX8200-48PF2 member c0c5.2080.2a80 0 remote Ready
standby active
+---+ +---+ +---+
2/3| 2 |2/1--2/3| 1 |2/1--2/3| 3 |2/1
+---+ +---+ +---+
Standby u2 - Learn other units for 15 sec, protocols may not be ready in 55 s.
Current stack management MAC is c0c5.2080.1bbc
ICX8200-48PF Router# clear chassis unit-id 3 ps-device 1 led
ICX8200-48PF Router# clear chassis unit-id 3 ps-device 2 led
| Release version | Command history |
|---|---|
| 10.0.00 | This command was introduced. |