The SoftGRE Gateway Failback Trigger feature allows Access Points (APs) to automatically revert from a secondary to a primary gateway after a specified period. The SoftGRE Gateway Failback Trigger feature is designed to enhance the reliability and efficiency of network operations.

Feature Overview

When the primary gateway for SoftGRE tunnels experiences an outage, APs seamlessly transition to a secondary SoftGRE tunnel for continued operation. However, reverting APs to the primary gateway once it is restored can be challenging without automation. This feature introduces a configurable timer that automates this process, ensuring APs return to the primary gateway after it has been reachable for a set duration.

You can configure the timer from 60 through 1440 minutes, with a default setting of 60 minutes. You can enable or disable this feature through a toggle button labeled Gateway Failback Trigger in the SoftGRE profile on the controller interface. For instructions to access and create a SoftGRE profile, refer to Creating a SoftGRE Profile.

Note: By default, the Gateway Failback Trigger option is disabled.

Requirements

To implement this feature ensure the following requirements are met.

  • The feature is supported in SmartZone release 6.1.2 Patch 3 and release 7.1.1 and later.
  • You must configure a secondary gateway to ensure seamless failover and failback operations.

Considerations

Consider the following when configuring and using this feature:

  • The Gateway Failback Trigger and AAA Affinity features cannot be enabled simultaneously.

Best Practices

Here are some best practices to ensure the smooth functioning of this feature:

  • Start with the default timer setting of 60 minutes and adjust it as needed based on network performance and stability.
  • Regularly update the firmware to maintain compatibility and access the latest features.
  • Ensure the primary gateway is stable and reliable before setting a short failback timer.
  • Monitor the network performance to determine the optimal timer setting for your environment.

Prerequisites

Consider the following prerequisites before you start using the feature.

  • Ensure all APs and controllers are running the compatible firmware versions.
  • Configure the primary and secondary SoftGRE tunnels correctly before enabling the failback feature.