Configuring Alarm Settings
- Go to . The Alarm Settings page appears.
- Configure the Enable Alarm Light section. When the alarm lights are enabled, they appear on the Help and Logout bar in the upper right corner of the Web interface.
- In the
Email Notification section, configure the email alarm groups, including email addresses to which alarm
notifications are sent and alarm severities.
Note: To edit an existing email notification entry, in Email Addresses, click Edit and then in Severity Criteria, select the check boxes for the alarm severity for which you want to send notifications: options include Critical, Major, Minor and Warning. Also enter the email addresses to send notifications to; use a semi-colon (;) to separate multiple email addresses. Click the Save button in the Email Notification section the changes.
- From the
Select Groups tab, select the wireless groups to be monitored from the list so that email notifications
are sent for the alarms generated for these devices and click
Save.
- From the Select WLAN Controller tab, select the device to be monitored from the list so that email notifications are sent for the alarms generated for these devices and click Save.
- From the
Select ICX Switch tab, select the device to be monitored from the list so that email notifications
are sent for the alarms generated for these devices and click
Save.
UMM 2.2
- From the Select Alarm Type tab, select the alarm types which you want to generate for the selected devices and click Save.
- In the
User Customized Alarm section configure the alarm types by assigning a severity level and setting a threshold
value to each alarm type.
Among others, these alarms include:
- AP # of channel changes: Triggered when the number of channel changes per AP crosses either of the specified thresholds.
- AP # of clients: Triggered when the number of clients per AP crosses either of the specified thresholds.
- AP # of reboot: Triggered when the number of reboots per AP crosses either of the specified thresholds.
- AP lost connection: Triggered when an AP is continuously disconnected for the either of the specified thresholds (numbers of hours).
- AP traffic: Triggered when traffic on an AP crosses either of the specified thresholds (traffic in MB).
- Unleashed Multi-Site Manager server CPU usage: Triggered when CPU usage on Unleashed Multi-Site Manager crosses either of the specified thresholds (CPU usage percentage).
- ZD CPU usage: Triggered when CPU usage on a ZoneDirector crosses either of the specified thresholds (CPU usage percentage).
- Configure the Event Selection section by selecting (enabling) events that trigger alarms.
- Select each tab under the Event Selection section, and then select the check boxes for events that trigger alarms. You can also change the severity level that is assigned to each event.
- Click the Save button in the Event Selection section.
You have completed configuring the alarm settings.