Minor Mismatch for Stack Units
With a minor mismatch, an operating stack can still exist, but traffic is dropped from all ports except the stacking ports for units with the mismatched software. You can download the correct image to the mismatched devices from the active controller. A minor software mismatch means that there is no IPC or election algorithm change, but there is a release version disparity. Minor software mismatches can occur with patch release upgrades. The system logs and displays a message similar to the following.
Warning! put stack unit 2 to non-operational reason=image mismatch
The
show stack command displays output similar to the following.
ICX7850-32Q Router# show stack
T=31m6.8: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX7850-32Q active d4c1.9e18.3731 0 local Ready
2 S ICX7850-48FS standby d4c1.9e18.8dd9 0 remote NON-OP: image mismatch
active standby
+---+ +---+
=3/5| 1 |3/1==2/1| 2 |2/5=
| +---+ +---+ |
| |
|------------------------|Normally, the system recovers from a minor image mismatch using the Auto Image Copy
feature. However, if the feature has been disabled or if the configuration of a stack
unit does not match the configuration of the active controller, the stack unit does
not function. In this example, unit 2 is non-operational due to an image mismatch.
To correct this situation, use the
copy flash flash command. Refer to
Copying the flash image to a stack unit from the active controller.