ICX 8100 Stack Configuration Overview
Stacking is supported on ICX 8100-X models starting with FastIron firmware version 10.0.10h.
ICX 8100 Stacking Capability
| Stacking Capability | ICX 8100 | Additional Information |
|---|---|---|
| Topologies supported | Ring and linear | Refer to ICX 8100 stacking topologies for more information. |
| Maximum stack size | 4 | Stacking only. |
| Maximum stacking distance |
40 kilometers |
Refer to FastIron stacking distances and optics by device for more information. |
| ICX 8100 model combinations | Only the 8100-X models support stacking | If a "non 8100-X' model is added to a stack of 8100-X models, the stack will break. |
| Stacking ports |
4 or 2 X 10 Gbps ICX 8100-C08PF-X / C16P-X: ports 1/2/1 to 1/2/2 ICX 8100-48-X, ICX 8100-48P-X, ICX 8100-48PF-X, ICX 8100-24-X, and ICX 8100-24P-X models: ports 1/2/1 to 1/2/4 |
Stacking port speeds are auto-detected. |
| Valid-stack-port sets |
ICX 8100-C08PF-X / C16P-X: (x/2/1, x/2/2, 1) ICX 8100-24-X / 24P-X / 48-X / 48P-X / 48PF-X: (x/2/1, x/2/3, 2)
Note: The third
number in the set is the maximum number of ports in a stacking
trunk. The number "1" indicates a single stack-port only.
|
Refer to the definition of valid-stack-port set in Stacking Terminology for more information. Refer to ICX 8100 Stacking Topologies for port locations. |
| Reconfigurable ports | Use the stack-port
and stack-trunk commands to reconfigure ports. |
Stacking port speeds are auto-detected and cannot be configured. |
| Trunks |
The following maximum stacking trunk configurations are supported: ICX 8100-24-X / 24P-X / 48-X / 48P-X / 48PF-X models: stack-trunk 1/2/1 to 1/2/2, stack-trunk 1/2/3 to 1/2/4 |
See also "Linear-topology trunks" in this table. |
| Linear-topology trunks | The following maximum linear-topology trunks are
supported: ICX 8100-C08PF-X / C16P-X: 2-port linear-topology-trunk: stack-trunk x/2/1 to x/2/2 ICX 8100-24-X / 24P-X / 48-X / 48P-X / 48PF-X: 4-port linear-topology-trunk: stack-trunk x/2/1 to x/2/4 |
Refer to Configuring Two-unit Stack Linear-topology Trunks for more information. |
| Hitless switchover and hitless failover | Supported | Refer to Hitless Stacking. |
| License requirements |
All ICX 8100-X devices include a license for 10-Gbps stacking. |
For more information on ICX 8100 license options, refer to the RUCKUS FastIron Software Licensing Guide. |
| Configuration options | Manual and automatic, including stack interactive-setup and stack zero-touch provisioning | Refer to Stack Construction Methods. |
| Access methods | TFTP, SCP | Software images, boot images, and signatures can be downloaded to a stack using TFTP and SCP applications. Refer to the RUCKUS FastIron Software Upgrade Guide for more information. |
| Stacking commands | All stacking commands are supported on ICX 8100-X devices unless otherwise stated on the command reference page. | For detailed command descriptions and usage information, refer to the RUCKUS FastIron Command Reference Guide. |