NIC Settings

For vSZ-D deployments, configure at least two network interfaces. You can add more interfaces for bonding (Linux equivalent of NIC teaming) to improve redundancy and throughput.

  • Management Interface: Provides CLI access and connects the Data Plane to the vSZ control interface.
  • Data Interface: Handles user data traffic between APs and the wired network. Configure this interface for high performance and low latency.

    Note:
  • For vSwitch mode, set the port group security policies to accept Promiscuous Mode, MAC Address Changes, and Forged Transmits.
  • For PCI passthrough, verify that the NIC supports DPDK-compatible drivers and that the hypervisor allows direct device assignment.

Recommended NIC Types by Environment lists recommended NIC types for each environment:

Recommended NIC Types by Environment

Environment Management NIC Data NIC Driver Options
KVM (vSwitch) e1000 virtio
KVM (PCI Passthrough) e1000

1G: igb

10G: ixgbe

ESXi (vSwitch) e1000

e1000e

VMXNET3

ESXi (PCI Passthrough) e1000

e1000e

1G: igb

10G: ixgbe

For more information refer to: