Checking the Cloud Connection Status
ICX 7150, ICX 7650, and ICX 7850 switches have an LED that indicates when the device is managed from the cloud. The following table interprets the LED status. Refer to the FastIron hardware installation guide for the specific ICX device for more information.
Cloud LED Status
| Connection State | LED Status / Color |
|---|---|
| Connected | Solid Green |
| Attempting to connect (Connecting) | Slow flash green (one flash every two seconds) |
| Disconnected | Off |
| Receiving configuration from cloud | Fast flashing green (two flashes every seconds) |
The
show manager status command indicates when an ICX switch is managed from the cloud. The Operation Status:
Enabled field indicates that the ICX switch is connected to the cloud, and the State:
CLOUD SSH CONNECTED field indicates the ICX switch is being managed from the cloud.
When the ICX switch is disconnected from the cloud and managed locally, the Operation Status: Disabled, State: Disabled, and Previous State: CLOUD SSH CONNECTED fields are displayed.
The following example connects an ICX device to RUCKUS Cloud.
ICX# manager connect
ICX# show manager status
============ MGMT Agent State Info ===================
Config Status: None Operation Status: Enabled
State: CLOUD SSH CONNECTED Prev State: CLOUD SSH CONNECTING Event: NONE
SWR List : None
Active List : 34.66.162.73,
DHCP Option 43 : No
DHCP Opt 43 List : None
Backup List : None
Merged List : 34.66.162.73, 34.66.162.71, 34.66.162.72, 34.66.162.74
SZ IP Used : 34.66.162.71
Query Status :
Response Received
SSH Tunnel Status - :
Tunnel Status : Established
CLI IP/Port : 127.255.255.253/44294
SNMP IP/Port : 127.255.255.254/1461
Syslog IP/Port : 127.0.0.1/20514
HTTP SERVER IP/Port: 127.255.255.252/39691
HTTP CLIENT IP/Port: 127.0.0.1/5080
Timer Status : Not Running
The following example disconnects the ICX device from RUCKUS Cloud.
ICX# manager disconnect ICX# show manager status ============ MGMT Agent State Info =================== Config Status: Disabled Operation Status: Disabled State: DISABLED Prev State: CLOUD SSH CONNECTED Event: NONE SWR List : 10.176.160.115 Active List : None DHCP Option 43 : No DHCP Opt 43 List : None Backup List : None Merged List : 10.176.160.115 Switch registrar host: sw-registrar.ruckuswireless.com Switch registrar discovery retry count: 0 Switch registrar host resolve failure count: 1 SZ IP Used : 10.176.160.115 Query Status : Not Initiated SSH Tunnel Status - : Tunnel Status : Not Initiated CLI IP/Port : /0 SNMP IP/Port : /0 Syslog IP/Port : /0 HTTP SERVER IP/Port: /0 HTTP CLIENT IP/Port: /0 Timer Status : Not Running
Refer to the
show manager status command in the
RUCKUS FastIron Command Reference for more information.