Method 1: Prepare a New Topology by Reconfiguring PE IDs on the CB
- Disconnect PE unit 18 and 19 from the CB.
- Change the
pe-idconfiguration on CB port 1/1/10 (from 17, 18, and 19 to 17 and 19). - Add PE ID 18 under the configuration for SPX port 1/1/5.
- As shown in the CB configuration on the right in the previous figure, connect PE unit 18 to SPX port 1/1/5, and connect PE unit 19 to PE unit 17 on SPX port 1/1/10.
- Enter the
write memorycommand to save the configuration.
The following example changes the port configuration for SPX ports 1/1/10 and 1/1/5.
ICX7650-48F Router# configure terminal ICX7650-48F Router(config)# spx cb-config ICX7650-48F Router(config-spx-cb)# pe-id 1/1/10 17 19 ICX7650-48F Router(config-spx-cb)# pe-id 1/1/5 18 ICX7650-48F Router(config-spx-cb)# exit ICX7650-48F Router(config)# exit ICX7650-48F Router# write memory