Campus Fabric Layer 2 Considerations

In the CB (core) stack, Layer 2 forwarding is performed on the local unit. However, forwarding decisions for PE unit ports are made in the CB, not locally on the PE.

MAC learning is disabled in Campus Fabric PE units.

The CB stack maps each E-tag E-CID and its associated physical port to a virtual port. The CB supports Layer 2 forwarding between virtual ports and between virtual and physical ports. The CB is responsible for programming MAC addresses associated with the PE units for forwarding traffic to the PE units in the Campus Fabric domain.

VLAN filtering is performed in the CB. This means that on CB physical and virtual ports:

  • Tagged packets (with a matching VLAN) are allowed on an untagged port.
  • Untagged or priority tagged packets on a tagged port are not allowed and are dropped.
  • All tagged, untagged, and priority tagged packets are allowed on dual-mode ports.

By default, each PE port is guaranteed membership in a maximum of four VLANs, including the default VLAN. You can increase the number of allowable memberships per PE port to any value from 5 through 1024 using the max-vlan-per-pe-port command. The potential pool for configuring PE VLAN contains 4096 entries and does not include the four default VLANS provisioned for the PE. Pool counters begin to increment only with the fifth VLAN. Use the show spx pe-port-vlan-resource command to check the number of available entries. The current non-default max-vlan-per-pe-port setting is displayed in show running-config command output.

The following table summarizes Layer 2 feature support available in a Campus Fabric domain.

Layer 2 Feature Support in a RUCKUS Campus Fabric Domain

Feature Support

MAC FDB

  • Learning
  • Aging
  • Move
  • Delete
  • Bulk flush
  • Disable learning per port
  • Configurable MAC age timer

Yes for CB ports

Not supported for PE ports

Minimum age timer has increased to 60 seconds.

Port-based VLANs

  • Untagged
  • Tagged
  • Dual Mode

Yes for CB ports

Yes for PE ports

Dynamic and Application VLANs (Layer 2 MAC table)

Yes for CB ports

Not supported for PEs: Application VLANs

Static MMAC

Yes for CB ports

Not supported on PE ports

MAC port security

Yes for CB ports

Not supported on PE ports

Link aggregation

  • Static LAG
  • LACP
  • Keep alive LAG
  • Add/Delete/Enable/Disable port
  • Short/Long timeout
  • Trunk threshold
  • LAG hardware failover

Yes for CB ports

Not supported on PE ports

xSTP

  • Single/Global 802.1D
  • Single/Global 802.1W
  • Per VLAN 802.1D
  • Per VLAN 802.1W
  • 802.1S
  • Cisco PVST
  • BPDU Guard
  • Root Guard
  • Designated Guard
  • Error disable recovery
  • STP protect
  • Fast port span
  • Fast uplink span

Yes

Not supported for PEs: MSTP

Super-aggregated VLANs (SAV)/Q-in-Q using Tag Profile

Yes for CB ports

Not supported for PE ports

Topology Groups

  • STP
  • RSTP
  • MRP
  • VSRP

Yes for CB ports

Not supported for PE ports

VLAN Groups/VLAN range

Yes for CB ports

Not supported for PEs: VLAN Group

Metro Ring Protocol (MRP)

Yes for CB ports

Not supported for PEs

Private VLAN

  • Tagged/Untagged port
  • Isolated VLAN
  • Community VLAN
  • Primary VLAN
  • Inter-Switch Link (ISL)

Yes for CB ports

Not supported for PEs

UDLD

  • Untagged and tagged port
  • Per VLAN

Yes for CB ports

Not supported for PEs

VSRP

Yes for CB ports

Not supported for PEs

MCT

Yes for CB ports

Not supported for PEs

GVRP

Yes for CB ports

Not supported for PEs

Loop Detect

Yes for CB ports

Supported on untagged and dual-mode PE ports.

Strict mode loop-detection is not supported on strictly tagged PE ports.

The maximum loop detect interval value has been increased from 100 to 300 (30 seconds).

Link OAM

Yes for CB ports

Not supported for PEs

Ethernet OAM

Yes for CB ports

Not supported for PEs