Campus Fabric and IP Multicast Considerations
In the upstream direction (from a PE to a CB), the packets are tagged with an E-tag to identify the ingress PE or SPX port. In the downstream direction (from a CB to a PE), the packets are tagged with an E-tag to identify the egress PE ports. E-channel identifiers (E-CIDs) contained in the E-tag header are used to identify a single PE port or a set of PE ports.
Multicast E-CID and IEEE 802.1BR
The point-to-multipoint E-channels used for remote replication are identified by an E-CID with a value in the range of 0x1000 to 0x3FFF (values less than this are reserved for E-CIDs associated with point-to-point E-channels).
General Campus Fabric Multicast Considerations
Unless otherwise stated, Layer 2 and Layer 3 multicast features supported on a standalone ICX 7650, ICX 7750, or ICX 7850 are supported by the CB in a Campus Fabric domain, and the Layer 2 and Layer 3 scaling capacity are the same.