Step 2: Configure the MCT VLAN, MCT Session VLAN, Recommended MCT Keep-Alive VLAN, and ICL Forwarding Delay
To create the recommended MCT keep-alive VLAN and MCT session VLAN for RUCKUS-1 and RUCKUS-2 devices in the topology of Basic MCT configuration, enter the following commands.
- Create an MCT keep-alive VLAN by
adding the tagged ports to the VLAN.
RUCKUS-1# configure terminal RUCKUS-1(config)# vlan 3001 name MCT-keep-alive RUCKUS-1(config-vlan-3001)# tagged ethernet 1/2/1 RUCKUS-1(config-vlan-3001)# exit
RUCKUS-2# configure terminal RUCKUS-2(config)# vlan 3001 name MCT-keep-alive RUCKUS-2(config-vlan-3001)# tagged ethernet 1/2/1 RUCKUS-2(config-vlan-3001)# exit
- Create a session VLAN by adding the ICL static LAG ID to the VLAN, and disable the spanning tree protocol.
- For ICX devices running a router image, add the following commands in the session VLAN configuration mode. Create a router interface with session VLAN ID, and assign an IP address to the router interface.
- For ICX devices running a switch image, assign an IP address in the Global Configuration mode.
- (Optional) Configure a delay in seconds to
wait after the ICL link comes up before regular traffic can be transmitted.
During the delay, only BPDU traffic is forwarded. The default is 0. The valid
range is 0 through 30.
RUCKUS-1(config)# cluster mct_stack 1000 <-creates cluster enters cluster config mode RUCKUS-1(config-cluster-mct_stack)# icl-fwd-delay 3 RUCKUS-1(config-cluster-mct_stack)# exit RUCKUS-1(config)#
RUCKUS-2(config)# cluster mct_stack 1000 RUCKUS-2(config-cluster-mct_stack)# icl-fwd-delay 3 RUCKUS-2(config-cluster-mct_stack)# exit RUCKUS-2(config)#
- (Optional) Configure a delay in seconds to keep dynamic CCEP LAGs on a CCP peer
in blocking state while CCP comes up, for example, following a cluster-peer
reload, ICL flap, or cluster re-deployment or undeployment.
RUCKUS-1(config)# cluster mct_stack 1000 RUCKUS-1(config-cluster-mct_stack)# ccep-up-delay 300 RUCKUS-1(config-cluster-mct_stack)# exit RUCKUS-1(config)#
RUCKUS-2(config)# cluster mct_stack 1000 RUCKUS-2(config-cluster-mct_stack)# ccep-up-delay 300 RUCKUS-2(config-cluster-mct_stack)# exit RUCKUS-2(config)#
Note: The delay can be set to a value from 0 through 600 seconds. The recommended setting is 300. The default setting is 0, which disables the timer.
To implicitly configure the MCT VLAN and add the ICL as a tagged member of the VLAN, enter the following commands.
RUCKUS-1(config)# vlan 1000 name MCT-VLAN-example RUCKUS-1(config-vlan-1000)# tagged ethernet 1/1/1 to 1/1/3 lag 2
RUCKUS-2(config)# vlan 1000 name MCT-VLAN-example RUCKUS-2(config-vlan-1000)# tagged ether 1/1/1 to 1/1/2 lag 2