bfd min-tx

Configures Bidirectional Forwarding Detection (BFD) session parameters for Border Gateway Protocol (BGP).
Syntax
bfd min-tx transmit-time min-rx receive-time multiplier number
no bfdmin-tx transmit-time min-rx receive-time multiplier number
Command Default

The default parameters are used if BFD is enabled.

Parameters
transmit-time
Specifies the interval, in milliseconds, a device waits to send control packets to BFD peers. Valid values range from 50 through 50000 milliseconds. The default is 300.
min-rx receive-time
Specifies the interval, in milliseconds, a device waits to receive control packets from BFD peers. Valid values range from 50 through 50000 milliseconds. The default is 300.
multiplier number
Specifies the number of consecutive BFD control packets that must be missed from a BFD peer before BFD determines that the connection to that peer is down. Valid values range from 2 through 50. The default is 3.
Modes

BGP configuration mode

Usage Guidelines

It is recommended to use the defualt values.

This command is supported for ICX 7850 devices only.

The no form of the command restores the defaults.

Examples

The following example sets the BFD session parameters globally for a BGP instance.

device# configure terminal
device(config)# router bgp
device(config-bgp-router)# bfd min-tx 280 min-rx 300 multiplier 3
History
Release version Command history
08.0.90 This command was introduced.