Specifying IPv6 SNMP Parameters
You can specify an IPv6 host as a trap receiver to ensure that all SNMP traps sent
by the
RUCKUS device will go to the same SNMP trap receiver or set of receivers, typically
one
or more host devices on the network. To do so, enter the snmp-server host
ipv6 command.
You can restrict SNMP access so that the RUCKUS device can be accessed only by the IPv6 host address that you specify.
The following example shows how to configure an IPv6 host as an SNMP trap receiver and to restrict SNMP access to an IPv6 host address.
device# configure terminal device(config)# snmp-server host ipv6 2001:DB8:89::13 mypublic port 200 device(config)# write memory device(config)# management source-interface ethernet 1/2/1 protocol snmp device(config)# snmp-server enable traps holddown-time 40
device# configure terminal device(config)# snmp-server host ipv6 2001:DB8:89::13 mypublic port 200 device(config)# write memory device(config)# snmp-client ipv6 2001:DB8:89::23 device(config)# snmp-server trap-source ethernet 1/2/1 device(config)# snmp-server enable traps holddown-time 40
The following RUCKUS ICX devices support IPv6 for SNMPv3: ICX 7150, ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX 7850.