| 1. Image upgrade of UFI image using TFTP from FastIron release 08.0.80 onward does
not work on ICX 7650 devices.
|
TFTP
|
ICX7650
|
08.0.80, 08.0.80a, 08.0.80b, 08.0.80c, 08.0.80d
|
08.0.80f (TFTP will be supported when it is released.)
|
Due to an increase in UFI image size, image upgrade from the FastIron 08.0.80 release
to the FastIron 08.0.90 release does not work for ICX 7650 devices.
There are two possible workarounds:
(a) Use SCP to download the UFI image.
(b) Download application and boot images separately using TFTP.
|
2. The
show version command does not show correct image name on standby or stack members after image
upgrade.
|
USB image download
|
All ICX platforms
|
08.0.30, 08.0.40, 08.0.50, 08.0.60, 08.0.61, 08.0.70
|
--
|
The
show version command shows "eusb1" as the image name for standby units when the FastIron image
is downloaded from USB.
The image is downloaded correctly, and there is no functional impact.
The workaround is to download the images using the TFTP or SCP protocol.
|
| 3. Image download using USB of boot image does not work on standby or member units.
|
USB image download
|
All ICX platforms
|
08.0.30, 08.0.40, 08.0.50, 08.0.60, 08.0.61, 08.0.70
|
--
|
The boot image is not flashed to the standby controller unit when USB is used to upgrade
or downgrade a stack.
The workaround is to download the images using the TFTP or SCP protocol.
|
| 4. Warning messages are displayed on standalone units during copy of UFI images using
SCP.
|
SCP
|
All ICX platforms
|
08.0.80, 08.0.80a, 08.0.80b, 08.0.80c, 08.0.80d, 08.0.80f
|
--
|
The following warning message is displayed on standalone units while copying UFI images
using SCP. The image is downloaded correctly, and there is no functional impact.
WARNING: Possible failure on one of the member units while downloading the image.
Images may not be in sync after reloading.
The workaround is to download the images using TFTP.
|
| 5. USB image upgrade is not supported for stacking in FastIron release 08.0.80.
|
USB image download
|
All ICX platforms
|
All ICX platforms
|
--
|
Image upgrade using USB is not supported for stacking in FastIron release 08.0.80
and 08.0.80 patches. The workaround is to upgrade using the TFTP or SCP protocol.
|
| 6. Lower version of uboot is not guaranteed to work with higher version of the application
image.
|
--
|
All ICX platforms
|
All ICX platforms
|
--
|
Earlier versions of the ICX software does not support UFI and can cause mismatch between
uboot and application image versions. Using UFI takes care of keeping the versions
intact and avoid mismatch.
|
| 7. When a system is upgraded to FastIron 08.0.90 or later and then downgraded to a
pre-08.0.90 release, may cause mismatch between uboot and application versions.
|
--
|
All ICX platforms
|
All ICX platforms
|
--
|
Depending upon the mismatch, it may cause application to not boot the UFI image in
primary/secondary.
|