Campus Fabric general troubleshooting checklist

The following table lists some common problems and items you can check before contacting a technical support representative.

For information on stacking issues, refer to "Traditional Stack Troubleshooting" in the RUCKUS FastIron Stacking Configuration Guide. For information on technical support, refer to Contacting Ruckus Customer Services and Support.

A PE unit may not join the Campus Fabric domain for many reasons. For other reasons, a PE may not achieve a Ready state, or the PE may age out after entering the Ready state. Check the applicable items listed in the following sections when a PE fails.

Campus Fabric general troubleshooting checklist

Problem Items to check Related commands and instructions
1. PE unit is not responding or does not join CB. a. Cable is correctly connected and connecting port is up. On CB and PE port: show interfaces brief
b. PE unit shows up and is in Ready state.

On CB and PE: show running-config

On CB: show spx
c. All transit PE units are correctly connected and are in Ready state. On CB: show spx
d. All transit PE units are correctly configured. show spx debug port unit/slot/port (for all SPX LAG members)
e. CB configuration is correct. SPX is enabled (spx cb-enable is present in configuration).

On CB: show running-config

f. There is an SPX port or SPX LAG connection from the CB to the PE unit.

On CB: show running-config

On CB: show spx

show spx debug port unit/slot/port (for all SPX LAG members)

g. Is the PE unit stuck in sync?

Contact technical support.

2. Topology not supported. Is the configuration blocked? Review "Invalid Topology" message on console for details. If no message appears, check that maximum configuration limits for PEs or CBs have not been exceeded.
3. CB cannot assign PE ID.

Ports and connections are valid.

PE ID is available (not already in use or reserved).

The following message in the CB port log indicates the pe-id is reserved, but the topology of the joining PE does not match the reserved configuration:

"No available ID: must remove unused "pe-id."

In this case, you should remove the unused pe-id configuration.

4. Image mismatch. Is there a major image mismatch?

show stack

show spx

Path to FTP server is configured correctly.

The image folder is present.

FTP server is connected.

show running-config

Ping the server address to verify connectivity.

Auto image copy is disabled.

From CB: show stack detail

If auto image copy should be disabled, manually download the image from the CB to the PE unit, or reset the PE unit.

5. Configuration mismatch. PE configuration on CB matches actual PE modules. If the PE configuration on the CB does not match actual PE modules, remove the reserved configuration on the CB. Issue a no spx unit ID command to remove the reserved configuration of the PE unit ID. This causes the CB to relearn the correct modules for the PE unit. If the no spx unit xx command is blocked due to the configuration on the PE unit, remove the erroneous configuration.
6. A connected PE unit detaches from the CB. SPX LAG or SPX port status. If ports are down, investigate reasons. If ports are up, a further issue is indicated. Collect supportsave spx output for both CB and PE for further analysis. Call technical support for assistance.
7. SPX LAG issues are evident.

LAG configuration is correct.

Connections on both sides of the LAG match. Speeds on both sides match.

Ports in LAG are operational.

Topology is valid.

show spx debug lag all

Adding the distributed keyword to the command. Without the keyword, the command output is derived from the CB. The following example displays information on LAG members and connections directly from PE units.

show spx debug lag all distributed all-pe

8. LAG issues between PE ports are evident.

LAG configuration is correct.

show lag
9. Multicast traffic not being forwarded to one or more virtual ports.

Virtual ports are part of mcache OIF.

Run the show ip pim vrf vrf1 mc command on both the router and the joined PE locally and compare output.

Issues persist.

Contact technical support for any additional assistance.