show sdlan config
No command default.
Network mode
The show sdlan config command
displays the following information.
This command is supported only on the Edge device. The Network Summary section provides information about the uplink connection type for each network. It indicates whether the network traffic is bridged over the uplink port into the core network or tunneled to another Edge device.
The below example displays the SD-LAN service configuration information when executed on a Data Center Edge device.
Network# show sdlan config core-port: port1 sw-if-idx: 1 mac-age: 5 mins Total SDLAN services: 1 Total Remote SDLAN services: 0 Name: dc-sdlan ID: 2 UUID: SL0a669f6e6a894def96c75dac12 Local: Yes Total WLANs: 6 Network-Name WLAN-ID SSID-VLAN VENUE student-1 1 100 Bldg#1 student-2 2 110 Bldg#2 faculty-1 3 200 Bldg#1 faculty-2 4 210 Bldg#2 guest-1 5 120 Bldg#1 guest-2 6 220 Bldg#2 Networks Summary: Network-Name Venue Uplink-Conn-Types student-1 Bldg#1 bridge-to-core-network student-2 Bldg#2 bridge-to-core-network student-3 Bldg#1 bridge-to-core-network faculty-3 Bldg#2 bridge-to-core-network guest-1 Bldg#1 tunnel-to-peer(10.22.1.13) guest-2 Bldg#2 tunnel-to-peer(10.22.1.13)
| Release version | Command history |
|---|---|
| 2.1.0 | Supporting multi-venue feature. |
| 1.0.0 | This command was introduced. |