show tech-support

Displays technical support information.
Syntax
show tech-support [ cancel ]
Parameters
cancel
Cancels previous invocations of the show tech-support command.
Modes

User EXEC mode

Usage Guidelines

The show tech support command can produce extensive output.

Examples

The following example cancels previous invocations of the show tech-support command.

device# show tech-support 
Gathering Show Output,  This may take a while ...
^C
'show tech' cancelled through Ctrl-C.
Please run 'show tech cancel' command before collecting 'show tech' again
device# show tech cancel
Cancelling..it may take a while
Successfully Cancelled
device#
Note: Press Control-c to cancel the running tech-support session and run show tech cancel command before running the show tech-support command again.

Please confirm example
The following example displays output for the show tech-support command, including information about about optical monitor cached data.

device# show tech-support
Gathering Show Output,  This may take a while ...
Disable page display mode
=======================================================================
BEGIN: show web
TIME STAMP:  Fri Apr 19 02:20:56 2024

=======================================================================
HTTP server status: Disabled
HTTPS server status: Disabled
No web connection.
=======================================================================
TIME STAMP:  Fri Apr 19 02:20:56 2024

END: show web
=======================================================================
=======================================================================

BEGIN: show optic
TIME STAMP:  Fri Apr 19 02:20:56 2024

=======================================================================
Optical monitoring is not enabled for down Port 1/1/1.
Optical monitoring is not enabled for down Port 1/1/2.
Optic is not present on port 1/1/3
Optic is not present on port 1/1/4
Port 1/1/5 is copper and not capable of optical monitoring
Optic is not present on port 1/1/6
Optic is not present on port 1/1/7
Optic is not present on port 1/1/8
Optic is not present on port 1/1/9
Optic is not present on port 1/1/10
Port 1/1/11 is copper and not capable of optical monitoring
Optic is not present on port 1/1/12
Optic is not present on port 1/1/13
Optic is not present on port 1/1/14
Optic is not present on port 1/1/15
Optic is not present on port 1/1/16
Optic is not present on port 1/1/17
Optic is not present on port 1/1/18
Optic is not present on port 1/1/19
Optic is not present on port 1/1/20
 Port   Temperature    Voltage       Tx Power      Rx Power    Tx Bias Current
+-----+-------------+-------------+-------------+-------------+---------------+
1/1/21   29.8320 C    3.3318 volts  -002.2511 dBm   -002.0398 dBm     5.712 mA
        Normal          Normal       Normal         Normal         Normal

Optic is not present on port 1/1/22
Optic is not present on port 1/1/23
Optic is not present on port 1/1/24
Optical monitoring is not enabled for down Port 1/1/25.
Optic is not present on port 1/1/26
Optical monitoring is not enabled for down Port 1/1/27.
Optic is not present on port 1/1/28
Optical monitoring is not enabled for down Port 1/1/29.
Optic is not present on port 1/1/30
Optical monitoring is not enabled for down Port 1/1/31.
Optic is not present on port 1/1/32
Port 1/1/33 is copper and not capable of optical monitoring
Port 1/1/34 is copper and not capable of optical monitoring
Optic is not present on port 1/1/35
Port 1/1/36 is copper and not capable of optical monitoring
Optic is not present on port 1/1/37
Optic is not present on port 1/1/38
Optic is not present on port 1/1/39
Optic is not present on port 1/1/40
Optic is not present on port 1/1/41
Optic is not present on port 1/1/42
Optic is not present on port 1/1/43
Optic is not present on port 1/1/44
Optic is not present on port 1/1/45
Optic is not present on port 1/1/46
Optic is not present on port 1/1/47
Optic is not present on port 1/1/48
Port 1/2/1 is copper and not capable of optical monitoring
Optic is not present on port 1/2/2
Optic is not present on port 1/2/3
Port 1/2/4 media is invalid

                         100GBASE-SR4
                        ==================
 Port   Temperature    Voltage       Tx Power      Rx Power    Tx Bias Current
+-----+-------------+-------------+-------------+-------------+---------------+
1/2/5   31.8203 C    3.2178 volts  -000.0208 dBm   -000.5197 dBm     7.494 mA
        Normal          Normal       Normal         Normal         Normal

 Chan Rx Power #1  Rx Power #2    Rx Power #3    Rx Power #4
+----+-----------+--------------+--------------+---------------+
    -000.5197 dBm  -000.6243 dBm  -000.5462 dBm  -000.9323 dBm
        Normal         Normal         Normal         Normal

 Chan  Tx Bias #1   Tx Bias #2     Tx Bias #3     Tx Bias #4
+----+-----------+--------------+--------------+---------------+
       7.494 mA       7.494 mA       7.494 mA       7.494 mA
        Normal         Normal         Normal         Normal

 Chan Tx Power #1  Tx Power #2    Tx Power #3    Tx Power #4
+----+-----------+--------------+--------------+---------------+
    -000.0208 dBm  -000.1376 dBm  -000.1112 dBm  -000.1596 dBm
        Normal         Normal         Normal         Normal

Optic is not present on port 1/2/6
Optic is not present on port 1/2/7
Optic is not present on port 1/2/8
...

The following example displays output for the show tech-support command, including information configured breakout ports.

device# show tech-support
Disable page display mode
=======================================================================
BEGIN: show running-config
TIME STAMP:  Wed Jan 31 11:44:05 2029

=======================================================================
Current configuration:
!
ver 10.0.20b_b265T233                                                        
!
stack unit 1
  module 1 icx7850-48f-sf-port-management-module
  module 2 icx7800-100g-8port-800g-module
  priority 128
  stack-port ethernet 1/2/1
  stack-port ethernet 1/2/5
stack unit 2
  module 1 icx7850-48fs-port-management-module
  module 2 icx7800-100g-8port-800g-module
  priority 10
  stack-port ethernet 2/2/1
  stack-port ethernet 2/2/5
stack unit 3
  module 1 icx7850-32q-port-management-module
  module 2 icx7800-100g-12port-1200g-module
  module 3 icx7800-100g-8port-800g-module
  stack-port ethernet 3/3/1
  stack-port ethernet 3/3/5
stack enable
stack rconsole-off
stack mac 903a.7205.5850
stack suggested-id 1                                              
!
hitless-failover enable
!
!
breakout ethernet 1/2/3 ethernet 3/3/2
!
!
global-rstp
!
!
vlan 1 name DEFAULT-VLAN by port
 spanning-tree 802-1w
!
!
!
!
!
!
ip route 0.0.0.0/0 10.177.130.1
!
!
!
!
!
!
!
!
!                                                                 
interface management 1
 ip address 10.177.130.47 255.255.255.128
!
interface ethernet 1/1/17
 disable
!
interface ve 1
 ipv6 enable
 ipv6 address autoconfig
!
!
!
!
!
!
!
!
username super password 1 $6$M78fhauw$RVLowACi5AjfbeFatYk/T3L7PASVgBxnzpLIgq8yun/rs8EHTtJUrSaojHJXliEOPFOCoCiBbjpvtaXYOBsXQ1    
!
aaa authentication login default local
!
aaa authentication web-server default local
!
ip dhcp-client ve default
!
logging console                                                   
!
!
web-management disable
!
!
!
snmp-server community 2 $U2kyXj1k ro
snmp-server community 2 $U2kyXj1k rw
!
manager registrar 
manager active-list 10.177.19.16
manager port-list 987
!
cli timeout 0
!
!
!
end
=======================================================================
...
History
Release version Command history
08.0.50 This command was introduced.
09.0.00 The acl, cluster, cpu, l2, l3, license, memory, multicast, multicast6, openflow, packet-loss, poe, and stack options are deprecated but data for these parameters is included in the output.
10.0.10f, 10.0.20b Information about optical monitor cached data is included in the command output.
10.0.20b_cd1 Information about configured breakout ports is included in the command output.