Node bond interface down

Node bond interface down alarm

Alarm

Node bond interface down

Alarm Type

nodeBondInterfaceDown

Alarm Code

809

Severity

Major

Aggregation Policy

From the event code 821 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 822.

Attribute

"nodeName”=”xxx”, “nodeMac”=”xxx”,

“ifName”=”xxxx”

Displayed on the web interface

Network interface [{networkInterface||ifName}] on node [{nodeName}] is down.

Description

This alarm is triggered when the network interface of a node is down.

Recommended Actions

Check if the network cables of both the physical interfaces are broken. Alternatively, check if the physical interfaces for this bond interface are broken. Please send the log files stored in the path -
/opt/ ruckuswireless/controller/log/system to RUCKUS support for analysis.