Cluster upgrade failed

Cluster upgrade failed alarm

Alarm

Cluster upgrade failed

Alarm Type

upgradeClusterFailed

Alarm Code

807

Severity

Major

Aggregation Policy

From the event code 815 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 814.

Attribute

"clusterName”=”xxx”, “nodeName”=”xxx”,

“nodeMac”=” xx:xx:xx:xx:xx:xx”, “fromVersion”="x.x",

“toVersion”="x.x"

Displayed on the web interface

Cluster [{clusterName}] could not be upgraded from [{fromVersion}] to [{toVersion}]. Reason:[{reason}].

Description

This alarm is triggered when a version upgrade of a cluster fails.

Recommended Actions

Check the disk usage. Try restoring the communication between nodes for a few more times. If the backup continues to fail or if you encounter Python script errors, please collect and send the complete system log files (stored in the path - /opt/ ruckuswireless/controller/log/system to RUCKUS support for analysis. Possible causes:

  • Insufficient disk space
  • Communication between nodes might be broken.
  • Errors due to the underlying Python script.