License threshold exceeded License threshold exceeded alarm Alarm License threshold exceeded Alarm Type licenseThresholdExceeded Alarm Code 960 Severity Critical 90%Major 80% Aggregation Policy From the event code 960 an alarm is raised for every event. A single event triggers a single alarm. Attribute “perc”=”xxx”, "nodeMac"="xx:xx:xx:xx:xx:xx”, "nodeName"="box1","licenseType"="SG00" Displayed on the web interface [{licenseType}] limit reached at [{perc}%]. Description This alarm is triggered when maximum number of licenses is utilized. Recommended Actions Check the license purchase and usage numbers. Alternatively, you would need to buy new licenses. Parent topic: harp://6a7214064c282d8ad6c44b90/pr/ORIGINAL/RUCKUS%20SmartZone%20(LT-GA)%20Alarms%20and%20Events%20Reference%20Guide%20(SZ144_vSZ-E_vSZ-H),_v1_GUID-0D5774F3-3095-499A-9B2D-C4F479DA5900/Threshold%20Alarms=GUID-A112BB81-C6C6-412C-B960-434984CE8F11=6=en-US=.xml