Displaying Stack Chassis Information

The show chassis command displays chassis information for each stack unit. Output resembles the following example for the first unit in a stack.

ICX7650-48P Router# show chassis
The stack unit 1 chassis info:

Power supply 1 not present
Power supply 2 (AC - PoE) present, status ok
        Model Number:   23-0000142-02
        Serial Number:  BLD2M39NM74
        Firmware Ver:   32.67
Power supply 2 Fan Air Flow Direction:  Front to Back

Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2

Fan controlled temperature: 35.3 deg-C

Fan speed switching temperature thresholds:
                Speed 1: NM<----->54       deg-C
                Speed 2:       46<-----> 70 deg-C (shutdown)

Fan 1 Air Flow Direction:  Front to Back
Fan 2 Air Flow Direction:  Front to Back
Slot 1 Current Temperature: 32.3 deg-C (Sensor 1), 41.6 deg-C (Sensor 2), 35.5 deg-C (Sensor 3), 36.0 deg-C (Sensor 4), 35.5 deg-C (Sensor 5), 41.1 deg-C (Sensor 6), 54.5 deg-C (Sensor 7), 37.0 deg-C (Sensor 8)
Slot 2 Current Temperature: Empty / Powered Down
Slot 3 Current Temperature: NA
        Warning level.......: 65.0 deg-C
        Shutdown level......: 70.0 deg-C
Boot Prom MAC : d4c1.9e14.6905
Management MAC: d4c1.9e14.6905

Field Definitions for the show chassis Command

Field

Description

Power supply 1

The status of the primary power supply

Power supply 2

The status of the secondary power supply, if present

Fan 1 through Fan 4

The status of the cooling fans, including speed, temperature reading, temperature range, and airflow direction

Fan controlled temperature

Measured temperature reading

Fan speed switching temperature thresholds (Speed 1, Speed 2)

Operating ranges for fan speeds 1 and 2, with the shutdown temperature indicated at the upper end of the temperature range for speed 2

Current temperature (by component)

Current temperature readings, in degrees Centigrade, for CPU, left fan, right fan, module fan, left power supply, right power supply, left front, middle front, right front, and back 40 Gbps module

Back 40G module Temperature Readings

For the rear 40 Gbps module, current temperature, warning level temperature, and shutdown level temperature

Exhaust Side Temperature Readings

From the air exhaust side of the chassis, the current temperature reading, the warning level temperature setting, and the shutdown level temperature setting

Intake Side Temperature Readings

The current temperature reading from the air intake side of the chassis

Boot Prom MAC

The MAC address of the boot prom

Management MAC

For the active controller only, the management MAC address