Checking Hardware after an Upgrade Failure
You can perform a few basic checks if you suspect a hardware failure.
When the system resets as the result of an upgrade failure, you may see output similar to the following example.
###### LOGS #################### Sent SIGTERM to all processes Sent SIGKILL to all processes Requesting system reboot Restarting system. Ruckus Networks Bootloader: 10.2.1b61T255 (Jun 07 2022 - 08:22:27 -0700) Model: ICX8200 ... snipped +++++++++++++++++++++++++++++++++ SKU Type : ICX8200-48PF CPU CPLD Revision: 02.2b Boot Loader Flash: Primary FI Image to Boot : Primary +++++++++++++++++++++++++++++++++ Enter 'b' to stop at boot monitor: 0
- To stop the reset and open the boot prompt, enter b.
- At the boot prompt, enter the
hwinfocommand to display basic hardware information as shown in the following example.ICX8200-Boot> hwinfo ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ SKU Type : ICX8200-48 System CPLD Version : 07.04 (LATTICE) Hardware Revision : DVT (Beta) 1 CPU ID (REV ID) : 0x9821 (1) Bootloader Booted From : Primary Dynamic Chip Select(Flash) : Flash 1 Next Boot Bank Select PCA9559 : Primary Boot Flash Flip : Disabled Dual Boot Watchdog : Disabled Warm Reboot Failure Record(CPLD) : 0x0 Cold Reboot Failure Record(CPLD) : 0x0 Reset Cause From CPLD : WARM_RESET (CPU_RESET_REQ) ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
- To verify installed image files, enter the
show_imagecommand at the boot prompt as shown in the following example.ICX8200-Boot> show_image =========================== Primary: 78449856 bytes read in 2830 ms (26.4 MiB/s) RDR10000(78449856) Secondary: 79850488 bytes read in 2880 ms (26.4 MiB/s) RDR10000_b429(79850488) Golden Image: 103492651 bytes read in 3854 ms (25.6 MiB/s) RDR10000_b395(103492651) ===========================
- To reset
hardware and memory, enter the