Considerations and Limitations for Group Tables

You must take into account a number of considerations and limitations when you configure group tables for OpenFlow flows.

Group Table Configuration Considerations

  • RUCKUS ICX devices support all group types in the OpenFlow v1.3.0 specification.
  • Multiple actions are supported by a group. The following packet modifications are supported through these actions for group types Indirect, Select and Fast failover:
    • Modify a VLAN
    • Modify the source MAC address
    • Modify the destination MAC address
    • Decrement the TTL
    • Pop VLAN
  • Each action bucket can have only one output port.
  • Each OpenFlow port can be a part of any number of groups.
  • A group entry can include ports from different slots and ports with different speeds.
  • Group tables are not impacted based on the OpenFlow type on the interface (Layer 2 or Layer 3 or Layer23 and hybrid interfaces).
  • To disable OpenFlow on interfaces, the interface must be removed from any group entry first.

Group Tables Limitations

For configuring OpenFlow, consider the following limitations.

  • Watch_group is not supported in the Fast failover group type.
  • Policy-based routing (PBR) or Transparent VLAN flooding cannot be configured along with the group table when OpenFlow v1.3.0 is enabled and vice versa.

Group All Limitations

  • To multicast flow-matching traffic to all action buckets, all action buckets are executed every time for the group All.
  • A packet is replicated for the output port in each bucket. Only one packet is processed for each bucket of the group.

Group Indirect Limitations

  • The group Indirect executes one defined action bucket in a group. Only one action bucket can exist and it is executed every time.
  • Group Indirect supports one and only one bucket in each group entry.

Group Select Limitations

  • To load balance flow-matching traffic to all action buckets, one of the action buckets is chosen each time for the group Select.
  • Weighted load balancing for group Select is not supported.
  • Group chaining is not supported.
  • Individual bucket statistics are not supported.

Group Fast Failover Limitations

  • The group Fast failover executes the first live bucket. Each action bucket associated with a specific port or group determines the "liveness" of the bucket.
  • The buckets are selected in the defined sequence.
  • On a stack unit fast failover, traffic convergence takes up to 3 seconds.
  • If no buckets are live, packets are dropped.