Enabling DOM

Complete the following steps to enable DOM.
Note: DOM is supported only on RUCKUS optics.
  1. Use the optical-monitor command to enable digital optical monitoring, and specify the polling and alarm interval. Enter one of the following versions of the command:
    • Enable digital optical monitoring and specify an alarm interval.

      device(config)# optical-monitor 18
      Enable optical monitoring and set alarm/warn interval to 18 minute(s) 
      

    • Enable digital optical monitoring, without specifying an alarm interval, to set the alarm interval to the default.
      device(config)# optical-monitor 
      Enable optical monitoring and set alarm/warn interval to default(8 minutes)
      
    The default alarm interval for the ICX 7450, ICX 7550, ICX 7650, and ICX 7850 is 8 minutes. The default alarm interval for the ICX 7250 and ICX 7150 is 3 minutes.

    Ports that are down are not included for optical monitoring by default configuration. To allow the monitoring for the down ports on an ICX device, enter the optical-monitor down-port-enable command.

  2. Use the interface command, specifying an interface, to enter interface configuration mode for the specified interface.
    device(config)# interface ethernet 1/1/1
    
  3. Use the optical-monitor command, without specifying a value, to enable optical monitoring on the specified port and set the default polling and alarm interval.
    device(config-if-e10000-1/1/1)# optical-monitor
    
  4. Use the exit command to return to global configuration mode.
    device(config-if-e10000-1/1/1)# exit
    
  5. Use the interface command, specifying a range of interfaces, to specify a range of interfaces.
    device(config)# interface ethernet 1/1/1 to 1/1/2
    
  6. Use the optical-monitor command, without specifying a value, to enable optical monitoring on the specified range of ports and set the default polling and alarm interval.
    device(config-mif-e10000-1/1/1-1/1/2)# optical-monitor
    
  7. Use the exit command to return to global configuration mode.
    device(config-mif-e10000-1/1/1-1/1/2)# exit
    
  8. Verify the alarm and warning interval.
    device(config)# show optic-timer 1/1/4 
    
    Optical monitoring timer Interval for Port 1/1/4 is 8 mins
    
  9. Verify the media device configuration.
    1. Display information about the media devices installed per device, per stack, and per port.
      device(config)# show media 
      
      Port 1/1/1:	 Type : 1G M-C (Gig-Copper)
      Port 1/1/2: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/3: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/4: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/5: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/6: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/7: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/8: 	Type : 1G M-C (Gig-Copper)
      Port 1/1/9: 	Type : 1G M-C (Gig-Copper)
      …
      Port 1/2/1: 	Type : 10GE SR 300m (SFP +)
      Port 1/2/2: 	Type : EMPTY
      Port 1/2/3: 	Type : 1G Twinax 1m (SFP)
      Port 1/2/4: 	Type : 1G Twinax 1m (SFP)
      
    2. Display information about the media device installed in a port.
      device(config)# show media ethernet 1/1/17
      
      Port 1/1/17: Type : 1GE M-SX(SFP)
      			Vendor: RUCKUS Networks. Version: A
      			Part# : 33210-100 Serial#: TAA11106M3GV
      
    3. Verify if your optics are official RUCKUS optics or another brand.
      device# show media validation ethernet 1/3/3
      
      Port       Supported   Vendor       Type                                                                            
      -------------------------------------------------------------
      1/3/3       Yes       RUCKUS       Type  : 10GE LR 10km (SFP+)  
      
  10. As a test, check the optical statistics for any enabled port.
    device(config)# show optic 2/1/1
    
     Port   Temperature     Tx Power      Rx Power       Tx Bias Current
    +-----+-------------+-------------+--------------+---------------------+
    2/1/1   32.2578 C    -002.5157 dBm  -002.8091 dBm    5.966 mA
            Normal       Normal         Normal           Normal 
    
  11. Verify the optic warning and alarm thresholds for any enabled port.
    device(config)# show optic thresholds 2/1/1