Configuring the CLI Banner
RUCKUS
devices can be configured to display a greeting message on users’ terminals when
they enter
the Privileged EXEC CLI level or access the device through Telnet. In addition,
a RUCKUS device can display a message on the console when an
incoming Telnet CLI session is detected.
- Enter the global configuration mode.
- Setting the message of the day
banner (MOTD) on the user terminal using a delimiting character.In this example, the delimiting character is "$" (dollar sign). The text in between the dollar signs is the content of the banner. The banner text can be up to 4000 characters long, which can consist of multiple lines.
- Configuring the requirement to
press the Enter key after the banner message is displayed.Requiring to press the Enter key after the MOTD is displayed is disabled by default.
- Set a privileged EXEC CLI level
banner.
device(config)# banner exec ASCII string c banner text c, where 'c' is a delimiting character <cr> device(config)# banner exec $ Enter TEXT message, End with the character '$'. TEST PRIVILEGE MODE $
You can configure the RUCKUS device to display a message when a user enters the privileged EXEC CLI level.
The following example shows how to configure CLI banner with "$" (dollar sign) as the delimiting character, requires pressing the Enter key.
device# configure terminal device(config)# banner motd $ Enter TEXT message, End with the character '$' Welcome!!! $ device(config)# banner motd require-enter-key device(config)# banner exec ASCII string c banner text c, where 'c' is a delimiting character <cr> device(config)# banner exec $ Enter TEXT message, End with the character '$'. TEST PRIVILEGE MODE $