Prerequisites
This topic specifies the resources and
systems required for configuring Network Segmentation.
- Minimum one Virtual SmartZone (vSZ) controller.
- The following SmartZone Data Plane (vSZ-D) controllers are supported -
- Minimum one SmartZone Data Plane (vSZ-D) controller.
- Two or more Access Points (APs) which are compatible with the 6.1.1 controller.
- For switch usage in network
segmentation:
new info for Phase 2
- One or more of the following switches as the distribution switch: RUCKUS ICX 7550, RUCKUS ICX 7650, or RUCKUS ICX 7850. (VxLAN is supported only on these models.)
- One or more of the following switches as access switches (also called "edge switches"). Switches: RUCKUS ICX 7150, RUCKUS ICX 7250, RUCKUS ICX 7450, RUCKUS ICX 7550, RUCKUS ICX 7650, or RUCKUS ICX 7850.
Note: Also, see "ICX Switch Preparation for Network Segmentation" below.
- Cloudpath server installed.
- vSZ controller installed and the cluster is operational.
- Admin account required for Cloudpath and vSZ systems.
- vSZ-D installed and managed by vSZ.
- Operational APs installed and managed by vSZ.
- Cloudpath should be able to communicate with SmartZone management interface.
- Ensure that the Cloudpath server certificate is in the controller trust store. Otherwise, the Network Segmentation feature will not work since the controller will not be able to communicate with Cloudpath.
- Ensure that all ICX switches
are upgraded to firmware version 09.0.10d (or any 09.0.10 patches that may
become available after 09.0.10d).
Note: The 10.0.00 release branch does not currently support network segmentation.
- It is necessary that the customer has licenses set up for DHCP and NAT servers.
ICX Switch Preparation for Network Segmentation:
- Distribution switches:
- The loopback interface must be able to communicate with, or be routeable to, the data interface of the data plane.
- The data path between distribution switches
and data planes must have an MTU size of at least 1568 bytes.
Phong - Is "bytes" correct here?
- The ICX switches must be able to communicate with, or be routeable to, the SmartZone control plane.
- Access switches: All client ports must be added to the web-authentication VLAN.
- Managing switches for network segmentation: