debug loop-detect
Allows the
RUCKUS devices to detect loops using the
RUCKUS Port Loop Detection (PLD) protocol and disable a port that is on the receiving end
of a loop. The loop is detected by sending Bridge Packet Data Unit (BPDU) test packets.
Usage Guidelines
This command initiates debugging the loop detection.
Examples
Note: Execute the command prior to configuring the modes.
The following example shows how to configure loop detection of a single port in strict mode.
device# debug loop-detect Configure loop-detection strict mode on port 1/1/25 : device(config-if-e1000-1/1/25)# loop-detection
When there is loop detection activity in the device, the debug information regarding loop detection is displayed on the console. The following example shows the output when the port goes into a disabled state because of loop detection (strict mode).
insert_disable primary 1/1/25, vlan=4096 Loop-detection: port 1/1/25 (vlan=1), put into errdisable state
The following example shows how to configure loop detection in a VLAN in loose mode.
Configure loop-detection loose mode on port vlan 2 : device(config-vlan-2)# loop-detection device(config-vlan-2)# insert_disable primary 1/1/31, vlan=2