ignore-temp-shutdown

Prevents shutdown of ICX 7150, ICX 7450, and ICX 7750 devices at the threshold shutdown temperature.
Syntax
ignore-temp-shutdown
no ignore-temp-shutdown
Command Default

By default, the function is disabled.

Modes

Global configuration mode

Stack-unit configuration mode

Usage Guidelines

The command is applicable only on RUCKUS ICX 7150, ICX 7450, and ICX 7750 devices.

Use the no form of the command to re-enable shutdown based on temperature threshold. The no form of the command disables the battleshort mode at global level and at unit level.

Either the global battleshort mode or unit-specific battleshort mode is enabled but not both.

This command can be executed at a global level and at a unit level. If the command is enabled or disabled at global level, it applies to all the units which are part of the stack. If the command is enabled or disabled at a unit level, it applies only to that unit alone in the stack. To execute this command at a unit level, specify the unit ID at the configuration mode.

Examples

The following example enables battleshort mode on a standalone device or globally on all stack units.

device(config)# ignore-temp-shutdown
Ignore temperature shutdown threshold has been enabled

The following example enables battleshort mode on an individual stack member.

device# configure terminal
device(config)# stack unit 2
device(config-unit-2)# ignore-temp-shutdown 
Ignore temperature shutdown threshold has been enabled in Stack unit 2
History
Release version Command history
08.0.60 The command was introduced.
08.0.61 The command was updated to support members of an ICX 7150 stack.