Supported ICX Models
Last Updated
Sep 03, 2026
models. 08.0.80a 09.0.10a and subsequent patches ICX 7150-C08P, -C08PT, -24F, -10ZP 08.0.92 09.0.10a and subsequent patches ICX 7250 08.0.80a 09.0.10a and subsequent patches ICX 7450 08.0.80a 09.0.10a and subsequent patches ICX 7550 08.0.95a - ICX 7650 08.0.80a - ICX 7750 08.0.80a 08.0.95 and
-
Last Updated
Aug 20, 2026
RUCKUS ICX Switches
Product Guides
Configure and Deploy
7250 or ICX 7450 stack to a PE chain or ring.................................................................................................. 62 Campus Fabric Manual Configuration
-
Last Updated
Aug 25, 2026
RUCKUS ICX Switches
Product Guides
Administer and Manage
.................................................................................................................................................................. 9 What’s new in this document There were no new features for this guide in FastIron software release 08.0.91. Supported hardware This guide supports the following Ruckus products: • RUCKUS ICX 7850 Series • RUCKUS ICX 7650 Series • RUCKUS ICX 7450 Series • RUCKUS ICX 7250
-
show chassis
Last Updated
Sep 03, 2026
EXEC mode The following is sample output from the show chassis command executed on an ICX 7450 device. device# show chassis The stack unit 1 chassis info: Power supply 1 not present Power supply 2 (AC - Regular) present, status ok Model Number: 23-0000144-02 Serial Number: 07W Firmware Ver: A Power
-
show chassis
Last Updated
Sep 03, 2026
EXEC mode The following is sample output from the show chassis command executed on an ICX 7450 device. device# show chassis The stack unit 1 chassis info: Power supply 1 not present Power supply 2 (AC - Regular) present, status ok Model Number: 23-0000144-02 Serial Number: 07W Firmware Ver: A Power
-
Configuring sFlow
Last Updated
Sep 03, 2026
, meaning that, on average, one out of every N packets is sampled. The sflow sample command in global configuration mode or port mode specifies N, the denominator of the fraction. The sampling rate must be set depending on the input traffic rate. On RUCKUS ICX 7250, ICX 7450, ICX 7550, ICX 7650, and ICX
-
Configuring sFlow
Last Updated
Sep 03, 2026
, meaning that, on average, one out of every N packets is sampled. The sflow sample command in global configuration mode or port mode specifies N, the denominator of the fraction. The sampling rate must be set depending on the input traffic rate. On RUCKUS ICX 7250, ICX 7450, ICX 7550, ICX 7650, ICX 7750
-
RUCKUS ICX Switch Port Extender Deployment Guide
Last Updated
Sep 02, 2026
units should be available for use. If ICX 7450 units are running FastIron 08.0.30 or earlier versions, the units should be manually upgraded to a FastIron 08.0.50 or later image before PE units are enabled to bring them up as SPX clients. If ICX 7250 units are running FastIron 08.0.30 or earlier
-
Supported ICX Models
Last Updated
Sep 03, 2026
ICX 7150-ES devices. 08.0.80a 09.0.10a and subsequent patches 10.0.10f and subsequent patches ICX 7150-C08P, -C08PT 08.0.92 09.0.10a and subsequent patches ICX 7250 08.0.80a 09.0.10a and subsequent patches ICX 7450 08.0.80a 09.0.10a and subsequent patches ICX 7550 08.0.95a - ICX7550-4X25GF 10.0.10h
-
Supported ICX Models
Last Updated
Sep 03, 2026
and subsequent patches 10.0.10f and subsequent patches ICX 7150-C08P, -C08PT 08.0.92 09.0.10a and subsequent patches ICX 7250 08.0.80a 09.0.10a and subsequent patches ICX 7450 08.0.80a 09.0.10a and subsequent patches ICX 7550 08.0.95a - ICX 7550-24XZP 10.0.20b_cd2 - ICX 7650 08.0.80a - ICX 7750