SmartZone Image Signing
SmartZone Image Signing enhances upgrade security by verifying digital signatures on software images. Beginning with Release 7.3, SmartZone validates controller and Data Plane upgrade images and installs only authentic, unmodified software.
Feature Overview
SmartZone Image Signing enhances software upgrade security by validating the authenticity and integrity of upgrade images before installation. During an upgrade, SmartZone verifies the image signature and certificate chain to ensure that the software originates from a trusted source and has not been modified or corrupted. If the image does not meet the signing requirements for the target upgrade path, SmartZone rejects the image and prevents the upgrade from proceeding. This validation process helps protect the system from unauthorized, tampered, or invalid software installations.
A software image can be either signed or unsigned:
- Signed image: Contains a digital signature that SmartZone validates during the upgrade process.
- Unsigned image: Does not contain a digital signature and is accepted only for specific backward-compatibility upgrade paths.
Use the following tables to determine the required image type for your upgrade scenario. The required image type depends on the upgrade method, running version, and target version:
SmartZone Controller Upgrade Through the SmartZone GUI or CLI
| Running Version | Target Version | Required Image |
|---|---|---|
| Earlier than Release 7.3 | Earlier than Release 7.3 | Unsigned XIMG |
| Earlier than Release 7.3 | Release 7.3 or later | Unsigned XIMG |
| Release 7.3 or later | Earlier than Release 7.3 | Not supported (downgrade) |
| Release 7.3 or later | Release 7.3 or later | Signed XIMG |
Data Plane Upgrade Through the SmartZone GUI
| Running Version | Target Version | Required Image |
|---|---|---|
| Earlier than Release 7.3 | Earlier than Release 7.3 | Unsigned XIMG |
| Earlier than Release 7.3 | Release 7.3 or later | Signed XIMG |
| Release 7.3 or later | Earlier than Release 7.3 | Not supported (downgrade) |
| Release 7.3 or later | Release 7.3 or later | Signed XIMG |
Data Plane Local Upgrade Through the Data Plane CLI
| Running Version | Target Version | Required Image |
|---|---|---|
| Earlier than Release 7.3 | Earlier than Release 7.3 | Unsigned XIMG |
| Earlier than Release 7.3 | Release 7.3 or later | Unsigned XIMG |
| Release 7.3 or later | Earlier than Release 7.3 | Not supported (downgrade) |
| Release 7.3 or later | Release 7.3 or later | Signed XIMG |
SmartZone Controller Wipeout Upgrade Through the SmartZone Web Setup Wizard
| Running Version | Target Version | Required Image |
|---|---|---|
| Earlier than Release 7.3 | Earlier than Release 7.3 | Unsigned XIMG |
| Earlier than Release 7.3 | Release 7.3 or later | Unsigned XIMG |
| Release 7.3 or later | Earlier than Release 7.3 | Unsigned XIMG |
| Release 7.3 or later | Release 7.3 or later | Signed XIMG |
Validation Failures and Events
If image validation fails, SmartZone rejects the upload, displays an error message, and generates a system event that can help identify and troubleshoot the cause of the failure. Validation failures may occur when:
Requirements
The following conditions are necessary for utilizing this feature:
- SmartZone release 7.3.0 and later support this feature.
- For Data Plane upgrades through the SmartZone web interface, a signed image is required for Release 7.3 or later. SmartZone rejects unsigned images that do not meet the signing requirements. Release 7.3 Data Plane platforms provide signed images for SmartZone GUI upgrades and regular images for local Data Plane CLI upgrades.
Considerations
Consider the following when configuring and using this feature:
- Verify the MD5 checksum of the SmartZone image file before uploading it to the administrative interface for a system upgrade. This verification helps ensure that the image file has not been corrupted or modified. You can obtain the MD5 checksum from the RUCKUS Support Portal.
Best Practices
This feature has no special recommendations for feature enablement or usage.
Prerequisites
This feature has no prerequisites to feature enablement or usage.