Displaying information with the show spx command

Enter the show spx command on the active controller to display information on the Campus Fabric topology.

The show spx command output in the following example shows a two-member ICX 7750 CB stack with one attached ICX 7450 PE unit, PE 17. The command was entered on the active controller, and the second stack member is available to take over as the standby.

ICX7750-26Q Router# show spx
T=3h24m20.3: alone: standalone, D: dynamic cfg, S: static
ID  Type          Role    Mac Address   Pri  State Comment
1 S ICX7750-26QXG active  cc4e.2438.7280 0   local  Ready
3 S ICX7750-26QXG standby 748e.f8f9.6300 0   remote Ready
17 S ICX7450-48GF spx-pe  cc4e.246c.f190 N/A remote Ready
active       standby
+---+        +---+
| 1 |2/4--2/1| 3 |
+---+        +---+
          +----+
1/1/5--4/1| 17 |
          +----+

Enter the show spx command on a PE unit to display local information as shown in the following example. The "S" after the PE ID (17) indicates that the configuration for this PE has been saved (is "static").


[PE]rconsole-17@ICX7450-48F Router# show spx
T=53m13.0: alone: standalone, D: dynamic cfg, S: static
ID   Type         Role   Mac Address    Pri State Comment
17 S ICX7450-48GF spx-pe cc4e.246c.f190 N/A remote Ready
    +----+
-4/1| 17 |
    +----+

You can add a parameter to the show spx command to display information about different aspects of the Campus Fabric topology.

ICX7750-26Q Router# show spx ?
  cb-port           Displays PEs attached to this port
  connections       Displays PE port to port connectivity
  csp               Displays CSP information
  debug             Displays SPX Debug commands
  lag               Displays spx-lag information
  mecid             Displays Dot1br Multicast ECID information
  multicast         Multicast related information
  pe-group          Displays PEs in a pe group
  pe-id             Displays this PE
  ring              SPX Ring infra information
  zero-touch ipc    Displays statistics for zero-touch ipc
  zero-touch log    Displays internal zero-touch log
  zero-touch status Displays current zero-touch status

Enter the show spx cb-port command to display a list of PE units attached to the port.

ICX7750-48F Router# show spx cb
  cb-port     Displays PEs attached to this port
ICX7750-48F Router# show spx cb-port 2/1/7
Show PEs attached to a CB port 2/1/7
T=3h46m16.0: alone: standalone, D: dynamic cfg, S: static
ID   Type          Role    Mac Address    Pri State   Comment                   
1  S ICX7750-48XGF active  cc4e.2438.7e80 128 local   Ready
2  S ICX7750-48XGF standby cc4e.246e.cd80 128 remote  Ready
19 S ICX7450-24G   spx-pe  cc4e.246c.e420 N/A remote  Ready



    standby      active                                                        
     +---+        +---+                                                        
  2/4| 2 |2/1--2/1| 1 |2/4                                                     
     +---+        +---+                                                       

            +----+                                                             
  2/1/7--2/3| 19 |                                                             
            +----+                                                             
                                                                              
ICX7750-48F Router#

Enter the show spx mecid command to display Multicast E-CID (ME-CID) information for the Campus Fabric domain.

The following example uses the keyword allocated to display information on allocated ME-CIDs.

ICX7750-48F Router# show spx mecid allocated
FSM-State : CREATE_P - created TX Pending, DELETE_P - deleted TX Pending
            DELETE_AW - Ack Waiting, CREATED - Stable State
Total MECID Allocated 2
-----------------------------------------------------
SNo   MECID PEs VPs  AW  State      Shr Elements
-----------------------------------------------------
1     4096  3   114  0   CREATED    No  {17/1/1 17/1/2 17/1/3 17/1/4 17/1/5 17/1/6 17/1/7 ...}
2     4097  3   11   0   CREATED    No  {17/1/1 17/1/2 17/1/3 17/2/3 17/2/4 18/1/1 18/1/2 ...}

The following command shows information for a specific ME-CID (4096).

ICX7750-48F Router# show spx mecid 4096
MECID State : CREATE_P - created Tx Pending, DELETE_P - deleted Tx Pending
              DELETE_AW - Ack Waiting, CREATED - Stable State
VP State    : ADD_P - Added Tx Pending, REMOVE_P - Removed Tx waiting
            : ADDED - Stable State
MECID: 4096 Total PEs: 3, Epoch: 0, FSM State: CREATED, SetId: 0x0, AW: 0
   1. PE: 17, Total VPs: 54, Ack_waiting: 0, CP Added: Yes
      (17/1/1 (cp) ADDED),  (17/1/2 (cp) ADDED),  (17/1/3 (cp) ADDED),  (17/1/4  ADDED),  (17/1/5  ADDED),  
      (17/1/6  ADDED),  (17/1/7  ADDED),  (17/1/8  ADDED),  (17/1/9  ADDED),  (17/1/10 ADDED),  
      (17/1/11 ADDED),  (17/1/12 ADDED),  (17/1/13 ADDED),  (17/1/14 ADDED),  (17/1/15 ADDED),  
      (17/1/16 ADDED),  (17/1/17 ADDED),  (17/1/18 ADDED),  (17/1/19 ADDED),  (17/1/20 ADDED),  
      (17/1/21 ADDED),  (17/1/22 ADDED),  (17/1/23 ADDED),  (17/1/24 ADDED),  (17/1/25 ADDED),  
      (17/1/26 ADDED),  (17/1/27 ADDED),  (17/1/28 ADDED),  (17/1/29 ADDED),  (17/1/30 ADDED),  
      (17/1/31 ADDED),  (17/1/32 ADDED),  (17/1/33 ADDED),  (17/1/34 ADDED),  (17/1/35 ADDED),  
      (17/1/36 ADDED),  (17/1/37 ADDED),  (17/1/38 ADDED),  (17/1/39 ADDED),  (17/1/40 ADDED),  
      (17/1/41 ADDED),  (17/1/42 ADDED),  (17/1/43 ADDED),  (17/1/44 ADDED),  (17/1/45 ADDED),  
      (17/1/46 ADDED),  (17/1/47 ADDED),  (17/1/48 ADDED),  (17/2/1  ADDED),  (17/2/2  ADDED),  
      (17/2/3  ADDED),  (17/2/4  ADDED),  (17/3/1  ADDED),  (17/4/1  ADDED),  
   2. PE: 18, Total VPs: 30, Ack_waiting: 0, CP Added: No
      (18/1/1  ADDED),  (18/1/2  ADDED),  (18/1/3  ADDED),  (18/1/4  ADDED),  (18/1/5  ADDED),  
      (18/1/6  ADDED),  (18/1/7  ADDED),  (18/1/8  ADDED),  (18/1/9  ADDED),  (18/1/10 ADDED),  
      (18/1/11 ADDED),  (18/1/12 ADDED),  (18/1/13 ADDED),  (18/1/14 ADDED),  (18/1/15 ADDED),  
      (18/1/16 ADDED),  (18/1/17 ADDED),  (18/1/18 ADDED),  (18/1/19 ADDED),  (18/1/20 ADDED),  
      (18/1/21 ADDED),  (18/1/22 ADDED),  (18/1/23 ADDED),  (18/1/24 ADDED),  (18/2/1  ADDED),  
      (18/2/2  ADDED),  (18/2/3  ADDED),  (18/2/4  ADDED),  (18/3/1  ADDED),  (18/4/1  ADDED),  
      
   3. PE: 19, Total VPs: 30, Ack_waiting: 0, CP Added: No
      (19/1/1  ADDED),  (19/1/2  ADDED),  (19/1/3  ADDED),  (19/1/4  ADDED),  (19/1/5  ADDED),  
      (19/1/6  ADDED),  (19/1/7  ADDED),  (19/1/8  ADDED),  (19/1/9  ADDED),  (19/1/10 ADDED),  
      (19/1/11 ADDED),  (19/1/12 ADDED),  (19/1/13 ADDED),  (19/1/14 ADDED),  (19/1/15 ADDED),  
      (19/1/16 ADDED),  (19/1/17 ADDED),  (19/1/18 ADDED),  (19/1/19 ADDED),  (19/1/20 ADDED),  
      (19/1/21 ADDED),  (19/1/22 ADDED),  (19/1/23 ADDED),  (19/1/24 ADDED),  (19/2/1  ADDED),  
      (19/2/2  ADDED),  (19/2/3  ADDED),  (19/2/4  ADDED),  (19/3/1  ADDED),  (19/4/1  ADDED),  

The following example shows a summary of configuration options and statistics on ME-CID activity in the Campus Fabric domain.

ICX7750-48F Router# show spx mecid summary
  Manager Init          : Yes        Replication Group Sharing : No
  Use PE CSP for TX     : Yes        Epoch                     : 0
  Reconciliation Pass   : 0          Replication Id            : 0
  ECID Partition        : Enabled    Global Timer running      : No
  ECID sharing          : No        
DEFAULT    4096    16383   12288   LRU
SWITCHING  4096    8191    4096    ACENDING
ROUTING    8192    16383   8192    DECENDING
  -----------------------------------------------------------------------------
                      alloc in-use  avail get-fail    limit  get-mem  size init
  -----------------------------------------------------------------------------
  MECID info           1000      2    998        0   232000        3    66 1000
  PE info               400      6    394        0    92800       12    52  400
  VP info             10000    125   9875        0  2320000      255    32 1000
  TX Q                 1000      0   1000        0   232000       31    12 1000
  PE Msg               1024      0   1024        0   237568       78    56 1024

  Total memory in used: 476144 bytes
ICX7750-48F Router#
ICX7750-48F Router# show spx mecid topology 
Total Cascade Port(CP): 2
   1. CP-TR(e2/1/41)  :-->[e17/2/4]PE_17[TR(e17/1/1)]-->[TR(e18/1/1)]PE_18

   2. CP-TR(e2/1/7)   :-->[e19/2/3]PE_19  

Enter the show spx pe-group command followed by the group name to display a list of PE units in a PE group.

ICX7750-48F Router# show spx pe-group GROUP1
Show PEs attached to pe-group GROUP1 (port 2/1/41)
T=17h57m5.5: alone: standalone, D: dynamic cfg, S: static
ID   Type          Role    Mac Address    Pri State   Comment                   
1  S ICX7750-48XGF active  cc4e.2438.7e80 128 local   Ready
2  S ICX7750-48XGF standby cc4e.246e.cd80 128 remote  Ready
17 S ICX7450-48P   spx-pe  cc4e.248b.da60 N/A remote  Ready
18 S ICX7450-24G   spx-pe  cc4e.246c.e3f8 N/A remote  Ready

    standby      active                                                        
     +---+        +---+                                                        
  2/4| 2 |2/1--2/1| 1 |2/4                                                     
     +---+        +---+                                                       

            +----+        +----+                                               
 2/1/41--2/4| 17 |1/1==1/1| 18 |                                               
            +----+        +----+                                               

Enter the show spx pe-id command followed by the PE number to display information for a specific PE.

ICX7750-48F Router# show spx pe-id 17
Show the sub-stack containing spx unit 17
T=3h51m3.8: alone: standalone, D: dynamic cfg, S: static
ID   Type          Role    Mac Address    Pri State   Comment                   
1  S ICX7750-48XGF active  cc4e.2438.7e80 128 local   Ready
2  S ICX7750-48XGF standby cc4e.246e.cd80 128 remote  Ready
17 S ICX7450-48P   spx-pe  cc4e.248b.da60 N/A remote  Ready
18 S ICX7450-24G   spx-pe  cc4e.246c.e3f8 N/A remote  Ready

    standby      active                                                        
     +---+        +---+                                                        
  2/4| 2 |2/1--2/1| 1 |2/4                                                     
     +---+        +---+                                                       

            +----+        +----+                                               
 2/1/41--2/4| 17 |1/1==1/1| 18 |                                               
            +----+        +----+                                               

Enter the show spx ring command with the desired parameter to show information for a specific ring, for all rings, or for PE chains in the Campus Fabric domain.

The following example displays all rings in the Campus Fabric domain.

ICX7750-48F Router# show spx ring all

  ------------------------------------------------------------------------------------
  Ring Id |FSM State |CB port  Lag  |Remote CB port  Lag  |Log Block Link
  ------------------------------------------------------------------------------------
  1        ACTIVE     1/1/2    3072  1/1/3           3073   PE29x--xCB1/1/3
  2        ACTIVE     3/1/19   3076  3/1/45          3078   CB3/1/19x--xPE26
  3        ACTIVE     2/1/12   3075  3/1/31          3077   PE27x--xPE28
  4        ACTIVE     1/1/5    3079  2/1/9           3074   PE19x--xPE20

The following example displays information for a specific ring. Ring IDs can be derived from the show spx ring all command.

ICX7750-48F SPX# show spx ring  2

  -------------------------------------------------------------------------------------
  Ring Id |FSM State |CB port  Lag  |Remote CB port  Lag  |Log Block Link
  -------------------------------------------------------------------------------------
  2        ACTIVE     3/1/19   3081  3/1/45          3083   PE26x--xPE25
  
CB chains Information:

  

----------------------------------------------------------------------------------------------
  CB Port    Lag  | Epoch |Ring    Id      FSM State|Remote CB port  Lag  |         Chain
  

---------------------------------------------------------------------------------------------

  3/1/19     3081  75      YES     2       ACTIVE    3/1/45          3083   PE26x--xPE25


PE chain information connecting to CB port 3/1/19 [Lag 3081]
             -----------------------------------------------------------------------------
             PE Id | Epoch | FSM state |Uplink port|Casc port|Log Block|Prev PE|Next PE
             -----------------------------------------------------------------------------
             PE26   75      ACTIVE      26/2/2      26/4/1    YES       --      x--x



          PE chain information connecting to remote CB port 3/1/45 [Lag 3083]
             -----------------------------------------------------------------------------
             PE Id | Epoch | FSM state |Uplink port|Casc port|Log Block|Prev PE|Next PE
             -----------------------------------------------------------------------------
             PE25   75      ACTIVE      25/2/1      25/3/1    YES       --      x--x

The following example shows output for all PE chains in the Campus Fabric domain.

ICX7750-48F SPX# show spx ring chain

  ----------------------------------------------------------------------------------------------
                             SPX CB [CASC PORT] CHAINS

  CB Port Lag | Epoch|Ring Id  FSM State|Remote CB port Lag | Chain
  ----------------------------------------------------------------------------------------------
  1/1/2   3072  75    YES  3   ACTIVE    1/1/3          3073  PE23--PE24x--xPE29
  1/1/3   3073  75    YES  3   ACTIVE    1/1/2          3072  PE29x--xPE24--PE23
  2/1/12  3079  75    YES  1   ACTIVE    3/1/31         3082  CB2/1/12x--xPE27--PE28
  3/1/3   3080  75    YES  4   ACTIVE    1/1/5          3084  PE22--PE21--PE20--PE19--PE18--PE17x--xCB1/1/5
  3/1/19  3081  75    YES  2   ACTIVE    3/1/45         3083  PE26x--xPE25
  3/1/31  3082  75    YES  1   ACTIVE    2/1/12         3079  PE28--PE27x--xCB2/1/12
  3/1/45  3083  75    YES  2   ACTIVE    3/1/19         3081  PE25x--xPE26
  1/1/5   3084  75    YES  4   ACTIVE    3/1/3          3080  CB1/1/5x--xPE17--PE18--PE19--PE20--PE21--PE22

The following example shows output for a specific PE chain (connected to CB port 3/1/19) in the Campus Fabric domain.

ICX7750-48F SPX# show spx ring chain 3/1/45

  --------------------------------------------------------------------------------------------------
  CB Port    Lag  | Epoch |Ring    Id      FSM State|Remote CB port  Lag  |         Chain
  --------------------------------------------------------------------------------------------------
  3/1/45     3083  75      YES     2       ACTIVE    3/1/19          3081   PE25x--xPE26


          PE chain information connecting to CB port 3/1/45 [Lag 3083]
             -----------------------------------------------------------------------------
             PE Id | Epoch | FSM state |Uplink port|Casc port|Log Block|Prev PE|Next PE
             -----------------------------------------------------------------------------
             PE25   75      ACTIVE      25/2/1      25/3/1    YES       --      x--x


          PE chain information connecting to remote CB port 3/1/19 [Lag 3081]
             -----------------------------------------------------------------------------
             PE Id | Epoch | FSM state |Uplink port|Casc port|Log Block|Prev PE|Next PE
             -----------------------------------------------------------------------------
             PE26   75      ACTIVE      26/2/2      26/4/1    YES       --      x--x

Enter the show spx csp command followed by desired parameters and the PE units you for which you want to display Control and Status Protocol (CSP) information that can help in troubleshooting issues. The information displayed is derived from the CB.

Enter the show spx csp distributed command followed by the PE units from which you want to receive information to display CSP information directly from the PE or PEs specified.

The following example shows CSP information received directly from PE units 23 and 29 as indicated by the use of the keyword distributed on the command line.

ICX7750-48F Router# show spx csp distributed units 23 29

*********************
Response from PE 23:
*********************

   CSP Oper: yes, Attach time: 1m22.0, up time: 11 hour(s) 48 minute(s) 38 second(s)  
   PE Spx Lag id: 2, cur state up, IPC/ECP Port: 23/2/3
   Number of Traffic Class: 8 
   Priority Flow Control: no 
   CSP control ECID handshake complete: yes 
   CSP control ECID: 555  
   CSP Alternate control ECID: 556 
   PE is in Ring (Status: Active), Logical Block: 1 
   Total number of configured ports: 566 
   CSP number of create port requests sent: 54 
   CSP last Tx Trans ID=3, last Rx Trans ID=6
   ECP txErrors=0, sequence=10 firstSeq=10 lastSeq=9 firstAckIdx=0 ackIdx=0
   Next PE: None 
   Previous PE: None 
   Local CSP Major version is 1 Minor version 1
   Peer  CSP Major version is 1 Minor version 1
   Oper  CSP Major version is 1 Minor version 1

*********************                                             
Response from PE 29:
*********************

   CSP Oper: yes, Attach time: 1m13.6, up time: 11 hour(s) 48 minute(s) 44 second(s)  
   PE Spx Lag id: 2, cur state up, IPC/ECP Port: 29/2/3
   Number of Traffic Class: 8 
   Priority Flow Control: no 
   CSP control ECID handshake complete: yes 
   CSP control ECID: 1035  
   CSP Alternate control ECID: 1036 
   PE is in Ring (Status: Active), Logical Block: 0 
   Total number of configured ports: 566 
   CSP number of create port requests sent: 54 
   CSP last Tx Trans ID=3, last Rx Trans ID=9
   ECP txErrors=0, sequence=13 firstSeq=13 lastSeq=12 firstAckIdx=0 ackIdx=0
   Next PE: None 
   Previous PE: None 
   Local CSP Major version is 1 Minor version 1
   Peer  CSP Major version is 1 Minor version 1
   Oper  CSP Major version is 1 Minor version 1

Enter the show spx zero-touch status command to check whether Campus Fabric Zero-touch provisioning is enabled, active, or available.

The following example shows command output for a CB unit. The output indicates that both Campus Fabric (SPX) and zero-touch provisioning have been enabled. Two valid chains have been discovered, and three attached units have been added as PEs. IPC-over-Ethernet and ACL are used to copy new images to new units before reloading them as PEs if the new units have different images.

ICX7750-26Q Router# show spx zero-touch status
I cannot be discovered by zero-touch or spx interactive-setup. reason: cannot be a PE
zero-touch-enable and spx cb-enable are configured. Have done 19 probes
ZTP has discovered 2 valid chains and converted 3 PEs.
zero-touch-enable period: 3 minutes. Will trigger in 2 min 45 sec
ZTP postponed due to topology changes: 2
My MAC used in the IPC-over-Ethernet is 748e.f8f9.636e.
ACL #=0, ind=0

The following example shows output from a new unit. Neither SPX interactive-setup or zero-touch provisioning is in progress.

ICX7250-24 Router# show spx zero-touch status
I can be discovered by zero-touch or spx interactive-setup.
zero-touch-enable is not configured.
I am not assigned any PE ID
ACL #=0, ind=0

The following example shows output from a new unit during the image copy process. The referenced ACLs are used to forward image download packets. For example, packets with the destination MAC of 609c.9f2a.981c are forwarded to port 2/5. The lines '' My MAC used in image copy is 609c.9f04.68cf " and "609c.9f04.68cf me cpu" shows that this MAC is its own MAC, so packets sent to this MAC are trapped to CPU.

ICX7250-24 Router# show spx zero-touch status
I can be discovered by zero-touch or spx interactive-setup.
I am discovered by CB u2 748e.f8f9.6300. My assigned ID is 28.
Will clean up in 116.6 sec if no keep-alive. Recv last KA 3.4 sec ago.
zero-touch-enable is not configured.
Default deny-all ACL is installed
My MAC used in image copy is 609c.9f04.68cf.
CB is in image download mode.
ID=28 MAC=609c.9f04.68ac ZTP=1, D0=2/5 2/6 2/7 2/8  D1=2/1 2/3 2/4
ACL #=7, ind=7
0: 609c.9f04.68cf me cpu
1: 609c.9f2a.d49c  fwd 2/5 i=0
2: 609c.9f2a.981c  fwd 2/5 i=1
3: 609c.9f04.6fb3  fwd 2/5 i=2
4: 609c.9f04.5e8b  fwd 2/1 i=3
5: cc4e.246c.f1cc  fwd 2/1 i=4
6: 748e.f8f9.636e CB fwd 2/1 i=5
Can reach CB u2: MAC=748e.f8f9.636e port=1/2/1

The following example shows output from a standalone ICX 7450 with startup configuration flash memory. As indicated in command output, the unit can be converted to a PE using option 3 of the spx interactive-setup command.

ICX7450-48F Router# show spx zero-touch status
I cannot be discovered by zero-touch or spx interactive-setup option 2. reason: once had startup-configuration flash
I can be discoverd by spx interactive-setup option 3.
zero-touch-enable is not configured.

Enter the show spx zero-touch ipc command to display statistics on packets used in the zero-touch or spx interactive-setup process.

Check the following output fields:

  • Send message types: The type 4 (ZTP-request) count should not be 0. If the count is 0, check that the candidate PE units are connected to CB SPX ports or SPX LAGs, zero-touch ports, or to PE ports that are non-base module ports.
  • Recv message types: If type 3 (ZTP probe) count is 0, check that the candidate PEs are clean units. When it receives a ZTP request or probe, the PE console prints a warning message if it is not qualified.
  • Reliable mail, target MAC: The send count and success count should match. If they are not equal, some messages have not been acknowledged after repeated retransmission. In this situation, zero-touch or SPX interactive-setup may still be successful.
  • Possible errors: Check for system information on possible errors, such as corrupted packets.

The following example displays zero-touch IPC information.

ICX7750-26Q Router# show spx zero-touch ipc
V2, , src=748e.f8f9.6300, max_pkt_size=1468, recv 38, send 34
Message types have callbacks:
 3: ZTP-probe                         4: ZTP-request
 5: unreliable-mail                   6: reliable-mail
 7: test ipc packets                  8: cmd-to-new-unit
 9: KA-new-unit

Send message types:
    [4]=30,           [6]=4,
Recv message types:
    [3]=30,           [6]=8,

Statistics:
    send pkt num          :        34,    send pkt-msg num      :        34,
    recv pkt num          :        38,    send msg num          :        34,
    recv msg num          :        38,    pkt buf alloc         :        34,

    Reliable-mail        send  success  receive   duplic  T-ms
    target MAC              2        2        0        0     3
    unrel target MAC        0                 0

Possible errors:

Enter the show spx zero-touch log command to display detailed information on zero-touch-enable and spx interactive-setup processes. Search for Error! or Warning! messages for details on potential problems.

The following example indicates that port 1/1/47 links to an invalid chain that already contains a maximum number of PE units. The output also indicates a ZTP reliable mail message has not been delivered.

ICX7750-26Q Router# show spx zero-touch log
42.4516 ZTP chg_cb(old=0, new=4): I new-A, ZTP not enabled, , 1U 0P A4S0 I4A 1%
8m42.4057 init_zero_touch() init_T=5217 , 3U 0P A4S2 I4A 81%
9m46.4440 Send ZTP probes: u1, ports: 4/1/6 to 4/1/8 PEs: , 3U 0P A4S2 I4A
10m7.5115 cb_r_probe. rec#=2, load=173, inv [0] cc4e.248b.77b0,  rec#=2, exist mac=cc4e.246c.f190 <= cc4e.248b.77b0, 
cannot overwrite, 3U 0P A4S2 I4A
21m38.4824 ZTP, 12 .5min T, cb_state = 0, diff = 201 s, diff=201 > 120 sec, trigger probe, 3U 1P A4S2 I4A 20%
21m38.6988 Send ZTP probes: u1, ports: 4/1/6 to 4/1/8 PEs: pe19, , 3U 1P A4S2 I4A
28m40.3054 *** Error! 1/1/47 links to an invalid chain: (chain length=1 + PE 21 len 5 + PE 31 len 1) = 7 > max 6
, 3U 0P A4S2 I4A 90%
28m42.4057 *** Warning! ZTP rel_mail fail:  chain 0 type=8, len=102, CPU=90%, 3U 0P A4S2 I4A 90%