ICX 7150 Stack Configuration Overview

The following table provides an overview of ICX 7150 stacking capabilities.

ICX 7150 Stacking Capabilities

Stacking Capability ICX 7150 Additional Information
Topologies supported Ring and linear Refer to ICX 7150 stacking topologies.
Maximum stack size 8 units

Any combination of eligible ICX 7150 devices may be stacked.

From FastIron release 09.0.00 ICX 7150 stacks can contain a maximum of eight units.

Maximum stacking distance 10 Kilometers Refer to FastIron stacking distances and optics by device for more information.
Stacking ports

Four 1-Gbps / 10-Gbps ports on fixed module on front panel that are available for stacking only when configured for 10-Gbps operation

Note: ICX 7150-C10ZP and ICX 7150-C12P devices have two 1-Gbps / 10-Gbps ports that are available for stacking only when configured for 10-Gbps operation.

On most ICX 7150 models, module 3 on the front panel contains four ports that can be used as stacking or uplink ports.

On ICX 7150-C10ZP and ICX 7150-C12P devices, module 3 on the front panel contains two ports that can be used as stacking or uplink ports.

On ICX 7150-48ZP devices, module 2 on the front panel contains four ports that can be used as stacking or uplink ports.

Refer to ICX 7150 stacking topologies for module and port locations.
Valid-stack-port sets

On most models, (x/3/1, x/3/3, 2)

On ICX 7150-C10ZP and ICX 7150-C12P devices, (x/3/1, x/3/2, 1)

On ICX 7150-48ZP devices, (x/2/1, x/2/3, 2)

Note: The third number in the set is the maximum number of ports in a stacking trunk. One indicates stack-port only.

Refer to the definition of valid-stack-port set in Stacking terminology for more information.

Refer to ICX 7150 stacking topologies for port locations.

Reconfigurable ports Supported

Use the no stack-port command to reconfigure one stack port as a data uplink port.

Once licensed, stacking ports will come up automatically as 10-Gbps.

You can manually reconfigure 1-Gbps ports to licensed 10-Gbps ports and vice versa using the speed-duplex command. Refer to RUCKUS FastIron Software Licensing Guide for information.

Stack trunks Supported Refer to ICX 7150 stacking trunks.

ICX 7150-C10ZP and ICX 7150-C12P devices do not support stacking trunks.

Linear-topology trunks

ICX 7150-C10ZP, ICX 7150-C12P: stack-trunk x/3/1 to x/3/2

ICX 7150-24, ICX 7150-24F, ICX 7150-24P: stack-trunk x/3/1 to x/3/4

ICX 7150-48, ICX 7150-48P, ICX 7150-48PF: no linear-topology trunk

ICX 7150-48ZP: stack-trunk x/2/1 to x/2/4

A linear-topology trunk is allowed only in a two-unit stack. It places the ports from both directions into one trunk.

Refer to Configuring Two-unit Stack Linear-topology Trunks for more information.

Hitless switchover and hitless failover Supported Refer to Hitless stacking.
License requirements A 10-Gbps license is required to support stacking, except on ICX 7150-48ZP devices.

Two 10-Gbps ports are standard on ICX 7150-48ZP devices, and any additional 10-Gbps ports require a license. On other ICX 7150 models, all 10-Gbps ports require a license.

Licenses are available for additional 10-Gbps ports except on ICX 7150-C12P devices, which have only two available ports. Refer to the RUCKUS FastIron Software Licensing Guide for information.

Configuration options Manual and automatic, including interactive-setup and zero-touch provisioning Refer to Stack construction methods.
Access methods TFTP, SCP Software images, boot images, and signatures can be downloaded to a stack using TFTP and SCP. Refer to the RUCKUS FastIron Software Upgrade Guide for more information.
Stacking commands All stacking CLI is available on the ICX 7150 unless otherwise noted on the command reference page.